Author
Updated
10 Nov 2023Form Number
LP0652PDF size
33 pages, 982 KB* Only available in selected markets
Abstract
The ThinkSystem RAID 930 family of internal 12 Gbps SAS RAID controllers are high-performance RAID-on-chip (ROC) adapters. These adapters support RAID levels 0/1/10/5/50/6/60, and include an extensive list of RAS and management features.
This product guide provides essential presales information to understand the ThinkSystem RAID 930-4i, 8i, 16i and 24i adapters and their key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the adapters and consider their use in IT solutions.
Change History
Changes in the November 10, 2023 update:
- The adapter supports the intermixing of 24 Gb/s, 12 Gb/s, and 6 Gb/s drives; 24 Gb/s drives operate at 12 Gb/s - Technical specification section
Introduction
The ThinkSystem RAID 930 family of internal 12 Gbps SAS RAID controllers are high-performance RAID-on-chip (ROC) adapters. These adapters support RAID levels 0/1/10/5/50/6/60 as well as JBOD, and include an extensive list of RAS and management features.
The family is comprised of four adapters:
- The ThinkSystem RAID 930-4i supports up to four internal SAS and SATA drives
- The ThinkSystem RAID 930-8i supports up to eight internal SAS and SATA drives
- The ThinkSystem RAID 930-16i supports up to 16 internal SAS and SATA drives
- The ThinkSystem RAID 930-24i supports up to 24 internal SAS and SATA drives
The ThinkSystem RAID 930-8i is shown in the following figure.
Figure 1. ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
Did you know?
RAID on Chip-based controllers such as the RAID 930 adapters have a dedicated processor that offloads all RAID functions from the server's CPU. With hardware acceleration for RAID 5 and 6 operations plus dedicated memory for caching, the 930-8i, 16i and 24i offer the ultimate performance for ThinkSystem servers.
Part number information
The following table provides the ordering part numbers for the adapters.
The following figure shows the ThinkSystem RAID 930-16i.
Figure 2. ThinkSystem RAID 930-16i PCIe 12Gb Adapter
Technical specifications
The ThinkSystem RAID 930 Series internal RAID adapters have the following specifications:
- PCIe 3.0 x8 host interface
- 12 Gbps SAS/SATA RAID controllers, based on the Broadcom MegaRAID 9460 adapter family
- 2GB, 4GB or 8GB of integrated flash-backed cache
- Connectivity for up to 2, 8, 16 or 24 internal SAS or SATA drives
- Support for intermixing SAS and SATA HDDs and SSDs. Mixing SAS and SATA drives in the same array is not supported. Mixing of HDDs and SSDs in the same array is not supported.
- Support for intermixing of 24 Gb/s, 12 Gb/s, and 6 Gb/s drives; 24 Gb/s drives operate at 12 Gb/s
- Support for RAID 0, 1, 10, 5, 50, 6 and 60 standard (The 930-4i supports only RAID 0, 1 in the SN550 and RAID 0, 1, 5, 6 in the SN850 because those blade servers only support two and four drives respectively)
- Support for JBOD (non-RAID) drive state
- Support for up to 64 logical drives
- Support for logical drive sizes greater than 2 TB.
- Configurable stripe size from 64 KB up to 1 MB
- Supports 512e, 512n and 4K sector formatted drives
- Supports UNMAP command for SAS SSDs (JBOD and RAID volumes)
- Supports TRIM command for SATA SSDs (JBOD)
- Compliant with Disk Data Format (DDF) configuration on disk (CoD).
- S.M.A.R.T. support.
- Configuration through
- XClarity Provisioning Manager UEFI interface
- XClarity Controller web interface
- XClarity Administrator Configuration Patterns
- StorCLI command-line interface
- LSI Storage Authority (LSA) GUI interface
- UEFI Human Interface Infrastructure (HII)
Note: CacheCade is not supported by these adapters
The following table compares the specifications of the RAID 930 adapters.
* The 930-4i for use in the SN550 blade server only supports RAID 0 and RAID 1 because the server has only two drives. The 930-4i for use in the SN850 blade server only supports RAID 0, 1, 5 and 6 because the server has only four drives.
Features
The ThinkSystem RAID 930 adapters have the following standard features:
- MegaRAID FastPath SSD performance acceleration
MegaRAID FastPath software provides high-performance I/O acceleration for SSD-based virtual drives by using a low latency I/O path to increase the maximum I/O per second (IOPS) capability of the controller. This feature boosts the performance of applications with a highly random data storage access pattern, such as transactional databases.
- MegaRAID flash cache protection
MegaRAID flash cache protection uses NAND flash memory, which is powered by a CacheVault Power Module supercapacitor, to protect data that is stored in the controller cache. This module eliminates the need for a lithium-ion battery, which is commonly used to protect DRAM cache memory on PCI RAID controllers. To avoid the possibility of data loss or corruption during a power or server failure, flash cache protection technology transfers the contents of the DRAM cache to NAND flash using power from the offload power module. After the power is restored to the RAID controller, the content of the NAND flash is transferred back to the DRAM, which is flushed to disk.
- Auto-resume on array rebuild or array reconstruction after the loss of system power
Auto-resume uses non-volatile RAM (NVRAM) to save the rebuild progress during a host reboot or power failure to automatically resume from the last checkpoint. Auto-resume ensures that data integrity is maintained throughout the process. The card supports a number of features that can be implemented without rebooting the server. Applications, such as email and web server, benefit from avoiding downtime during the transition.
- Online Capacity Expansion
Online Capacity Expansion (OCE) allows the capacity of a virtual disk to be expanded by adding new physical disks or making use of unused space on existing disks, without requiring a reboot.
- Online RAID Level Migration
Online RAID Level Migration (RLM), which is also known as logical drive migration, can migrate a virtual disk from any RAID level to any other RAID level without requiring a reboot. System availability and application functionality remain unaffected.
- Fast initialization for quick array setup
Fast initialization quickly writes zeros to the first and last sectors of the virtual drive. This feature allows you to immediately start writing data to the virtual drive while the initialization is running in the background.
- Consistency check for background data integrity
Consistency check verifies that all stripes in a virtual disk with a redundant RAID level are consistent. The consistency check mirrors data when an inconsistent stripe is detected for RAID 1 and re-creates the parity from the peer disks for RAID 5 or RAID 6. Consistency checks can be scheduled to take place periodically.
- Extensive online configuration options and advanced monitoring and event notification
Management tools provide convenience for the configuration of logical volumes and alerting when errors have occurred or are about to occur.
- Patrol read for media scanning and repairing
Patrol read is a background sentry service that pro-actively discovers and corrects media defects (bad sectors) that arise normally as a disk drive ages. The service issues a series of verify commands, and if a bad block is discovered, the card's firmware uses RAID algorithms to re-create the missing data and remap the sector to a good sector. The task is interruptible based on controller activity and host operations. The firmware also provides an interface where the patrol read task can be initiated, set up for continuous operation, and terminated from a management application. Patrol read can be activated by a manual command or automatically.
- Global and dedicated hot spare with revertible hot spare support
A hot spare rebuilds data from all virtual disks within the disk group in which it is configured. You can define a physical disk as a hot spare to replace a failed drive. Hot spares can be configured as either global or dedicated. A global hot spare allows any physical drive to be designated as a hot spare. A dedicated hot spare allows the user to assign a hot spare drive to a particular array of the same drive type.
- Drive roaming
Drive roaming occurs when the physical disks are changed to different ports on the same controller. When the drives are placed on different channels, the controller detects the RAID configuration from the configuration data on the drives.
- MegaRAID SafeStore support for self-encrypting drive (SED) services
MegaRAID SafeStore encryption services offer instant secure erase and local key management for self-encrypting drives. This technology represents a step forward in securing data on a disk drive from any unauthorized access or modification resulting from theft, loss, or repurposing of drives. Instant secure erase permanently removes data when repurposing or decommissioning SEDs. SafeStore local key management provides the necessary management and protection of SEDs by using a simple pass phrase, security key identifier, and security key file that can be set and applied to all SEDs that are assigned to a RAID adapter. This feature removes the complexity of managing each SED’s unique encryption key, and it essentially relieves the administrator of most of the daily tasks of securing data.
- XClarity Provisioning Manager for pre-boot array configuration and management
Provisioning Manager is the ThinkSystem UEFI-based application that includes a RAID setup wizard to help you configure drive groups and virtual disks before installing or booting the operating system.
- XClarity Controller web interface for remote storage management
XClarity Controller (XCC) is the systems management processor integrated in all ThinkSystem servers. The XCC web interface allows you to perform storage inventory, create and edit virtual disks, view events, import a new controller configuration, and perform firmware updates on the adapter.
Note: MegaRAID CacheCade and MegaRAID Storage Manager are not supported.
The ThinkSystem RAID 930-24i is shown in the following figure.
Figure 3. ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
Server support
The following tables list the ThinkSystem servers that are compatible.
The ThinkSystem RAID 930-4i is shown in the following figure.
Figure 4. ThinkSystem RAID 930-4i-2GB 2 Drive Adapter Kit for SN550 (included heatsink not shown)
Operating system support
The following tables list the supported operating systems for the adapters:
1 The OS is not supported with EPYC 7003 processors.
1 The OS is not supported with EPYC 7003 processors.
1 The OS is not supported with EPYC 7003 processors.
1 The OS is not supported with EPYC 7003 processors.
Warranty
The adapters carry a 1-year limited warranty. When installed in a supported ThinkSystem server, the adapter assumes the server’s base warranty and any warranty upgrades.
Operating environment
The ThinkSystem RAID 930 Series adapters are supported in the following environment:
- Operating:
- Temperature: 10°C to 55°C (50°F to 131°F)
- Relative humidity: 20% to 90% (non-condensing)
- Storage
- Temperature with package: -40°C to 70°C (-40°F to 158°F)
- Relative humidity: 5% to 95% (non-condensing)
Agency approvals
The ThinkSystem RAID 930 adapters have the following agency approvals:
- FCC Part 15 Class A
- Australia/New Zealand (AS/NZS CISPR 22)
- Canada (ICES-003 Class B)
- Europe (EN55022/EN55024)
- Japan (VCCI V-3)
- Korea (RRA no 2013-24 & 25)
- RoHS compliant
- EN/IEC/UL 60950
- Taiwan (CNS 13438)
- USA (FCC 47 CFR part 15 Subpart B class B)
- WEEE
Related publications and links
For more information, see the following documents:
- ThinkSystem RAID 930 Installation and User Guide
https://serveroption.lenovo.com/storage_adapter_options/thinksystem_930_16i_8i_hba_ic/ - Broadcom MegaRAID 9460 User Guide (Note: Tri-Mode not supported by Lenovo)
https://docs.broadcom.com/doc/pub-005851 - ServerProven hardware compatibility:
http://www.lenovo.com/us/en/serverproven - Lenovo RAID Management Tools and Resources:
https://lenovopress.com/lp0579-lenovo-raid-management-tools-and-resources - Lenovo RAID Introduction
https://lenovopress.com/lp0578-lenovo-raid-introduction
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
AMD is a trademark of Advanced Micro Devices, Inc.
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the November 10, 2023 update:
- The adapter supports the intermixing of 24 Gb/s, 12 Gb/s, and 6 Gb/s drives; 24 Gb/s drives operate at 12 Gb/s - Technical specification section
Changes in the June 12, 2023 update:
- The adapters support up to 64 logical drives - Technical specifications section
- Add a link to the RAID 930 Installation and User Guide - Related publications and links section
Changes in the February 28, 2021 update:
- The server support tables are now automatically updated - Server support section
Changes in the November 20, 2020 update:
- Clarified support for TRIM/UNMAP commands - Technical specifications section
Changes in the May 5, 2020 update:
- Added SR645 and SR665 to the server support table - Server support section
Changes in the March 20, 2020 update:
- Added support statement for TRIM/UNMAP commands - Technical specifications section
Changes in the September 12, 2019 update:
- Added SE350, SR635 and SR655 to the server table - Server support section
Changes in the January 22, 2019 update:
- Added the new ThinkSystem SR670 RAID 930-8i 2GB Flash (supported only in the SR670)
Changes in the November 5, 2018 update:
- Added new servers: ThinkSystem ST50, ST250, SR150 and SR250
- Updated the list of supported operating systems
Changes in the July 17, 2018 update:
- New ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter, 4Y37A09721
- Updated the list of supported operating systems
First published: 11 July 2017
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The owner of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at [email protected].