Abstract
The Brocade X7 FC SAN Directors are high-performance, modular, chassis-based Fibre Channel networking devices that provides connectivity between servers, switches and storage systems to form the backbone of an enterprise FC storage area network. The X7 Directors provide up to 384 64Gb ports or up to 512 32Gb ports, enabling organizations to scale more devices, applications, and workloads.
This product guide provides essential pre-sales information to understand the X7 Directors, their key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the X7 Directors and consider their use in IT solutions.
Change History
Changes in the September 9, 2024 update:
- The following were updated with correct PNs and FC Transceivers and cables section:
- Brocade Secure 64-Gb SWL SFP-DD Transceiver, 4M27A65427
- Brocade Secure 64-Gb SWL SFP-DD Transceiver 8-pack, 4M27A65428
Introduction
The Brocade X7 FC SAN Directors are high-performance, modular, chassis-based Fibre Channel networking devices that provides connectivity between servers, switches and storage systems to form the backbone of an enterprise FC storage area network. The X7 Directors provide a modular building block, purpose-built for scalability to accommodate growth and power large-scale storage environments.
With a 50% latency reduction compared to the previous generation, X7 Directors maximize the performance of NVMe storage and high transaction workloads, eliminating I/O bottlenecks and unleashing the full performance of next generation storage.
The modular design provides flexibility with two customizable chassis that can scale on-demand for more devices, applications, and workloads, the X7-8 and X7-4. Both chassis utilize Brocade UltraScale ICL technology to scale out modular SANs while preserving blade ports for device connectivity and allowing flexible SAN design that supports core-edge or mesh topologies.
Figure 1. Brocade Gen 7 Director X7-8 (left) and X7-4 (right)
Did you know?
X7 Directors provide cyber resiliency with integrated security technology that protects mission critical operations by validating the integrity of Gen 7 hardware and software. With enhanced security and autonomous SAN technology, organizations can take the guesswork out of protecting and managing a network.
With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that offers "one stop shop" and single point of contact for delivery of leading-edge technologies and innovations from Lenovo and other leading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs, including end-user devices, servers, storage, networking, services, management software, and financing.
Key features
The Brocade X7 FC SAN Directors provide up to 512 ports, enabling organizations to scale more devices, applications, and workloads. With diverse deployment options, multiprotocol flexibility, and mixed blade capability, organizations can adapt and optimize their businesses to meet next-generation storage and server requirements. The X7 Directors support the concurrent use of both traditional Fibre Channel and NVMe storage traffic, allowing organizations to seamlessly integrate Gen 7 Fibre Channel networks with next generation NVMe-based storage, without a disruptive rip-and-replace.
The X7 Directors lay the foundation for the autonomous SAN. With autonomous SAN technology, the director harnesses the power of analytics and the simplicity of automation to optimize performance, ensure reliability, and simplify management. Leveraging these capabilities enables organizations to realize a self-learning, self-optimizing, and self-healing SAN.
The X7 Directors offer the following features and benefits:
- Scale more devices, applications, and workloads with up to 512 64 Gb links per chassis
- Maximize NVMe and high transaction workloads with 50% lower network latency
- Transform telemetry data into actionable insights to optimize performance and ensure reliability
- Automate actions to simplify management and resolve issues without intervention
- Increase visibility and simplify operations with a modern SAN management tool
- Safeguard mission-critical workloads from vulnerabilities with Gen 7 integrated security
- Seamlessly integrate next generation NVMe into the storage fabric without a disruptive rip-and replace
- Design flexible architectures to increase agility with concurrent Fibre Channel, NVMe, FICON, or FCIP connectivity
- Extend replication over distance with a highly scalable extension solution for Fibre Channel, IP, and FICON
- Enterprise bundle software (Fabric Vision, Extended Fabrics, Trunking, CUP and Integrated Routing) are included as standard features.
Components and connectors
The Brocade X7-4 Director with the airflow diversion kit is a 9U rack mount chassis that is built for midsize networks. It has four horizontal blade slots to provide up to 256 ports for device connectivity. An additional 16 UltraScale ICL connections provide 64 ports for chassis-to-chassis interconnect.
The Brocade X7-8 Director is a 14U rack mount chassis that is built for large enterprise networks. It has eight vertical blade slots to provide up to 512 ports for device connectivity. An additional 32 UltraScale Inter-Chassis Link (ICL) connections provide 128 ports for chassis-to-chassis interconnect.
In this section:
The port side of the X7-4 chassis has the following components:
- Four blade slots within the X7-4 chassis can be populated with optional port or extension blades. The chassis comes without port blades or extension blades, see Blades for ordering information.
- Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis). A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:
- USB port for firmware download and technical support data
- Serial console RJ-45 port
- 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
- 10/100/1000 Mb Ethernet RJ-45 port for service
- 10 Gb Ethernet RJ-45 port (reserved for future use)
- Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.
- Two redundant hot-swap active/active Core Routing blades (CR blades come with the chassis). Core routing blades contain ASICs that allow switching between up to four port blades, and each core routing blade provides 96 Fibre Channel backplane ports for port or extension blade connections and 32 front-end FC links that are mapped to 8 QSFP+ ports for inter-chassis links (ICLs). POD License Kits are sold separately.
The following figure shows the non-port side view of the X7-4 FC SAN Director.
The non-port side of the X7-4 chassis has the following components:
- Choice of hot-swap power supplies AC or High Voltage (two must be ordered together with the chassis). Dual-function high-voltage AC, high-voltage DC (HVAC/HVDC) power supply assembly: Converts AC or DC input to the required DC output power required for device operation. Each power supply assembly provides the following power outputs in Watts at the indicated AC and DC input rated voltages: 1450W (100–120 VAC); 2870W (200–277 VAC); 2870W (240–380 VDC). Most common is AC NPI power supply.
- AC power supply supporting non-port side air intake (NPI) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the non-port side to the port side of the device.
- AC power supply model supporting non-port side air exhaust (NPE) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the port side to the non-port side of the device.
- High voltage power supply model supporting non-port side air intake (NPI). This assembly has two fans that move the air from the non-port side to the port side of the device.
- High voltage power supply model supporting non-port side air exhaust (NPE). This assembly has two fans that move the air from the port side to the non-port side of the device.
- Choice of hot-swap cooling modules (two must be ordered together with the chassis and must match airflow of the power supplies)
- Non-port side air intake (NPI) moves the air from the non-port side to the port side of the device.
- Non-port side air exhaust (NPE) moves the air from the port side to the non-port side of the device.
The port side of the X7-8 chassis has the following components:
- Eight blade slots within the X7-8 chassis can be populated with optional port or extension blades. The chassis comes without port blades or extension blades, see Blades for ordering information.
- Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis) A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:
- USB port for firmware download and technical support data
- Serial console RJ-45 port
- 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
- 10/100/1000 Mb Ethernet RJ-45 port for service
- 10 Gb Ethernet RJ-45 port (reserved for future use)
- Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.
- Two redundant hot-swap active/active Core Routing blades (CR blades come with the chassis). Core routing blades contain ASICs that allow switching between up to eight port blades, and each core routing blade provides 192 Fibre Channel backplane ports for port or extension blade connections and 64 front-end FC links that are mapped to 16 QSFP+ ports for inter-chassis links (ICLs). POD License Kits are sold separately.
The following figure shows the non-port side view of the X7-8 FC SAN Director.
Figure 5. X7-8 FC SAN Director non-port side view
- Choice of hot-swap power supplies AC or High Voltage (four must be ordered together with the chassis). Dual-function high-voltage AC, high-voltage DC (HVAC/HVDC) power supply assembly: Converts AC or DC input to the required DC output power required for device operation. Each power supply assembly provides the following power outputs in Watts at the indicated AC and DC input rated voltages: 1450W (100–120 VAC); 2870W (200–277 VAC); 2870W (240–380 VDC). Most common is AC NPI power supply.
- AC power supply supporting non-port side air intake (NPI) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the non-port side to the port side of the device.
- AC power supply model supporting non-port side air exhaust (NPE) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the port side to the non-port side of the device.
- High voltage power supply model supporting non-port side air intake (NPI). This assembly has two fans that move the air from the non-port side to the port side of the device.
- High voltage power supply model supporting non-port side air exhaust (NPE). This assembly has two fans that move the air from the port side to the non-port side of the device.
- Choice of hot-swap cooling modules (three must be ordered together with the chassis and must match airflow of the power supplies)
- Non-port side air intake (NPI) moves the air from the non-port side to the port side of the device.
- Non-port side air exhaust (NPE) moves the air from the port side to the non-port side of the device
Port Blades and SX6 Extension Blades
The following figure shows the FC64-64 port blade.
Figure 6. FC64-64 port bladeThe Brocade FC64-64 Fibre Channel port blade with 32 SFP-DD ports provides 64 x 64G Fibre Channel ports with backward-compatibility support for 8, 16, and 32G Fibre Channel connectivity. The FC64-64 port blade enables industry-leading platform density for Gen 7 SAN configurations supporting up to 256 64-Gbps external ports in a single X7-4 chassis, and up to 512 64-Gbps external ports in a single X7-8 chassis. Leveraging this efficient, high-density designed blade, organizations can consolidate more device connectivity into a single fabric and reduce capital expenses by consuming less rack space. By utilizing fewer chassis, it lowers operational cost by reducing power consumption, cooling, and management. With industry-leading port density and increased bandwidth, organizations can effectively scale to meet data growth demands and drive efficiency by maximizing space utilization with room for future scaling of demanding IT applications. (Requires chassis use FOS 9.2 or later).
The following figure shows the 48-port blade.
Figure 7. 48-port blade (Image example is FC32-48)
There are multiple 48-port blades offerings. These blades contain 48 ports capable of Fibre Channel speeds up to 32 or 64 Gbps depending on model, and support up to 192 32-Gbps external ports in a single X7-4 chassis, and up to 384 32-Gbps external ports in a single X7-8 chassis. While most client will leverage SWL transceiver models, LWL models are available for those mainframe-connected environments or those needing connectivity over longer distances.
- The Gen 7 Brocade FC64-48 Fibre Channel port blade provides 48 x 64G Fibre Channel ports with backward-compatibility support for 8, 10, 16, and 32G Fibre Channel connectivity.
- The Brocade FC32-X7-48 Fibre Channel port blade provides 48 x 32G Fibre Channel ports with backward-compatibility support for 8, 10, and 16G Fibre Channel connectivity.
- The Gen 6 FC32-48 Fibre Channel port blade provides 48 x 32G Fibre Channel ports with backward-compatibility support for 4, 8, 10, and 16G Fibre Channel connectivity
The following figure shows the SX6 extension blade.
The SX6 Extension blade is intended as an extension platform to support Fibre Channel, FICON, and IP based storage data flows. Extension features enable you to use the existing IP wide area network (WAN) infrastructure to connect Fibre Channel and IP fabrics. Extension features support applications such as remote data replication (RDR), centralized backup, and data migration over very long distances. Extension tunnels, built on a physical connection between two extension switches or blades, allow Fibre Channel and IP I/O to pass through the IP WAN. The SX6 Extension blade can connect with an SX6 blade in another Brocade FC SAN Director or with a Brocade 7840 Extension Switch.
System specifications
The following table lists the Brocade X7-4 and X7-8 FC SAN Director system specifications.
Note: The supported hardware options and firmware features listed in this product guide are based on the Fabric OS version 9.X.
Models
The following table lists the X7-4 and X7-8 FC SAN Director Models.
The X7-4 and X7-8 FC SAN Director part numbers include the following items:
- One Director chassis that contains the following components:
- Two control processing blades
- Two core routing blades
- Enterprise Bundle SW license installed
- Integrated Routing SW license installed
- Ground lug kit
- Wrist strap
- X7-4 Specific
- Vertical Cable Management Comb
- Airflow diversion Kit (27"-31") and documentation
- 4-post rack mount Kit
- X7-8 Specific
- Cable Management Comb
- 14U rack mount kit (27"-31")
Configuration notes:
- Models come standard with CR blades, however in order to leverage the ICLs, ICL POD kits are required. See the Inter-Chassis Links section for details.
- Models do not include port blades or extension blades and will need to be ordered for the Director model. See the Blades section for details.
- Models do not include fan modules or power supplies and must be ordered together with the director model. See Cooling and Power supplies and cables for details.
- Models do not include power cords and must be ordered together with the director model. See Power supplies and cables for details.
Blades
The X7-4 and X7-8 FC SAN Directors support the port and extension blade options that are listed in the following table.
Blades can be mixed, but the maximum is four for the X7-4 and eight for the X7-8.
Port and extension blades come standard with all ports activated. They also include a specific number and type of transceivers, as indicated in the description of each part number. Additional transceivers and cables can be ordered. See Transceivers and cables for details.
Transceivers and cables
In this section:
Connectivity choices
With the flexibility of the X7-4 and X7-8 Directors, customers can choose the following connectivity technologies:
- SFP+ ports on the 48-port blades and SX6 extension blade
- For 64 Gb FC links, customers can use 64 Gb FC SFP+ SWL optical transceivers for distances up to 100 meters on OM4/OM5 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 64 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiber (SMF) optic cables. For extended distances, the 64 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables. (These transceivers are only available on Brocade FC64-48 Port Blade)
- For 32 Gb FC links, customers can use 32 Gb FC SFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 32 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiber (SMF) optic cables. For extended distances, the 32 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables.
- For 16 Gb FC links, customers can use 16 Gb FC SFP+ SW optical transceivers for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables. For longer distances, the 16 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ SMF cables. For extended distances, the 16 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables. (These transceivers are NOT supported on Brocade FC64-48 Port Blade)
- For 10 Gb FC links, customers can use 10 Gb FC SFP+ SW transceivers for distances up to 550 meters on OM4 or up to 300 meters on OM3 50 µ MMF cables, or 10 Gb FC SFP+ LW transceivers for distances up to 10 km on 9 µ SMF cables. 10 Gb FC operations allow metro connectivity by directly utilizing a fiber optic cable between sites or by creating multiple channels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM) technology.
- SFP-DD ports
- For 64G FC links, customers can use 64G FC SFP-DD SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables. These transceivers can operate at 64G, 32G, or 16G speeds.
- QSFP+ ports on the core routing blades:
- For 128 Gb FC inter-chassis links for connectivity between the X7-4 or X7-8 FC Directors, customers can use 128 Gb (4x 32 Gb) FC QSFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables.
Note: ICL trunks are formed automatically with corresponding 32 Gbps ports on different QSFP+ transceivers (ICL trunks cannot be formed with the 4x 32 Gbps ports on the same QSFP+ transceiver), and the trunking license is not required. - For 64 Gb FC inter-chassis links for connectivity between the X7-4 or X7-8 FC Directors and Brocade DCX 8510 Backbones, customers can use the following transceivers:
Note: ICL trunks are formed automatically with corresponding 16 Gbps ports on different QSFP+ transceivers (ICL trunks cannot be formed with the 4x 16 Gbps ports on the same QSFP+ transceiver), and the trunking license is not required.- 128 Gb (4x 32 Gb) QSFP+ SWL v2 optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables.
- 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 50 µ MMF cables.
- 4x 16 Gb FC QSFP+ LWL optical transceivers for distances up to 2 kilometers on parallel 9 µ SMF cables.
- 1/10 GbE SFP+ and 40 GbE QSFP+ ports on extension blades allow connection to IP WANs and allow Fibre Channel and IP I/O traffic to pass through the IP WAN through extension tunnels.
- For 1 GbE links, customers can use RJ-45 SFP transceivers with UTP cables up to 100 meters. Customers that need longer distances can use a 1000BASE-SX transceiver, which can drive distances up to 220 meters with 62.5 µ OM1 and up to 550 meters on 50 µ OM2 MMF cables, or the 1000BASE-LX transceivers that support distances up to 10 kilometers on 9 µ SMF cables.
- For 10 GbE links, customers can use a 10GBASE-SR transceiver that supports distances up to 300 meters on OM3 or up to 400 meters on OM4 50 µ MMF cables. For longer distances, the 10GBASE-LR transceivers can support distances up to 10 kilometers on 9 µ SMF cables.
- For 40 GbE links, customers can use the 40GBASE-SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 50 µ MMF cables. For longer distances, the 40GBASE-LR4 transceivers can support distances up to 10 kilometers on 9 µ SMF cables. For extended distances, the 40GBASE-ER4 transceivers can support distances up to 40 kilometers on 9 µ SMF cables.
- 1 GbE RJ-45 management ports on control processor blades: Customers can use UTP cables for distances up to 100 meters.
- For 128 Gb FC inter-chassis links for connectivity between the X7-4 or X7-8 FC Directors, customers can use 128 Gb (4x 32 Gb) FC QSFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables.
All port-blades come standard with transceivers that you see reflected in the descriptions. The SX6 extension blades come standard with 16x 32 Gb FC SWL or LWL SFP+ transceivers. The optional ICL bundles include eight Gen 7 FC QSFP+ or eight 4x32G SWL FC QSFP+ transceivers. Additional or different Fibre Channel or Ethernet SFP+, SFP-DD and QSFP+/QSFP28 transceivers can be ordered, if required.
Transceivers
The following table lists the supported transceiver options and optical cables.
Brocade secure transceivers: These new transceivers have features to ensure that you are using genuine Brocade components to maximize performance and reliability and to help avoid issues related to counterfeit products.
* The specific ELWL only operates at 32 Gbps and 16Gbps.
** ELWL Requires same optic type/part number on both ends (no-mixing) to assure interoperability.
The SFP-DD Cables specific for the FC64-64 port blade are listed in the following table.
Cabling requirements
The following table lists the cabling requirements for the directors.
Transceiver | Standard | Cable | Connector |
---|---|---|---|
128 Gb (4x 32 Gb) Fibre Channel | |||
128 Gb (4x 32 Gb) FC SWL QSFP+ (4M27A08820, 4M27A65422) | FC-PI-6 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables). 850 nm 50 µ MPO-MPO MMF cable:
|
MPO |
128 Gb (4x 32 Gb) FC 2km LWL QSFP+ (4M27A09986) | FC-PI-6 | 32GFC: 1310 nm 9 µ LC-LC SMF cable up to 2 km. | LC |
64 Gb (4x 16 Gb) Fibre Channel | |||
4x 16 Gb FC SWL QSFP+ (01KN805) | FC-PI-5 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables). 16GFC: 850 nm 50 µ MPO-MPO MMF cable up to 100 m (OM4) or up to 66 m (OM3). |
MPO |
64 Gb Fibre Channel | |||
64 Gb FC SWL SFP+ (4M27A65425, 4M27A65426) | FC-PI-6 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables). 850 nm 50 µ LC-LC MMF cable:
|
LC |
64 Gb FC LWL SFP+ (4M27A65433, 4M27A65434) | FC-PI-6 | 1310 nm 9 µ SMF cable: 64GFC, 32GFC, 16GFC: Up to 10 km. |
LC |
64 Gb FC ELWL SFP+ (4M27A65432) | FC-PI-5 | 1310 nm 9 µ SMF cable: 64GFC, 32GFC, 16GFC: Up to 25 km. |
LC |
32 Gb Fibre Channel | |||
32 Gb FC SWL SFP+ (4M27A65416, 4M27A65417) | FC-PI-6 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables), or the following 850 nm 50 µ MMF cables:
|
LC |
32 Gb FC LWL SFP+ (4M27A65418, 4M27A65419) | FC-PI-6 | 1310 nm 9 µ SMF cable:
|
LC |
32 Gb FC ELWL SFP+ (4M27A65424, 4M27A65431*) | FC-PI-6 | 1310 nm 9 µ SMF cable:
|
LC |
16 Gb Fibre Channel | |||
16 Gb FC SWL SFP+ (4M27A65411 / 4M27A65412) | FC-PI-5 | Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables). | LC |
16 Gb FC LWL SFP+ (4M27A65413 / 4M27A65414) | FC-PI-5 | 1310 nm 9 µ SMF cable:
|
LC |
16 Gb FC ELWL SFP+ (4M27A65415) | FC-PI-5 | 1310 nm 9 µ SMF cable:
|
LC |
10 Gb Fibre Channel | |||
10Gb FC SWL SFP+ (4M27A65420) | FC-10GFC | 850 nm 50 µ MMF cable:
|
LC |
10Gb FC LWL SFP+ (4M27A65421) | FC-10GFC | 1310 nm 9 µ SMF cable:
|
LC |
100 Gb (4x 25 Gb) Fibre Channel over Ethernet | |||
100Gb (4x25Gb) SR4 QSFP28 (4M27A09989) | 100GBASE-SR4 |
Up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables). 850 nm 50 µ MPO-4xLC MMF breakout cable up to 70 m (OM3) or up to 100m (OM4). |
MPO |
40 Gb Fibre Channel over Ethernet | |||
40Gb (4x10Gb) SR4 QSFP+ (4M27A09987) | 40GBASE-SR4 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables). 850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4). |
MPO |
40Gb SR QSFP+ BiDi (4M27A09988) | 40GBASE-SR BiDi |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables). 850 nm 50 µ LC-LC MMF cable up to 100 m (OM3) or up to 150 m (OM4). |
LC |
40 Gb Ethernet | |||
40 GbE SR4 QSFP+ (01KN813) | 40GBASE-SR4 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables). 850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4). |
MPO |
40 GbE LR4 QSFP+ (01KN817) | 40GBASE-LR4 | 1310 nm 9 µ SMF cable up to 10 km. | LC |
40 GbE ER4 QSFP+ (01KN821) | 40GBASE-ER4 | 1310 nm 9 µ SMF cable up to 40 km. | LC |
10 Gb Ethernet | |||
10 GbE SR SFP+ (49Y4216) | 10GBASE-SR |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables). 850 nm 50 µ LC-LC MMF cable up to 400 m (OM4) or up to 300 m (OM3). |
LC |
10 GbE LR SFP+ (95Y0540) | 10GBASE-LR | 1310 nm 9 µ SMF cable up to 10 km. | LC |
10 GbE DWDM SFP+ (01KN837) | 10GBASE-ZRD | 1550 nm 9 µ SMF cable up to 80 km. | LC |
1 Gb Ethernet | |||
1 GbE SX SFP (01KN825) | 1000BASE-SX |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables). 850 nm 50 µ LC-LC MMF cable up to 550 m. |
LC |
1 GbE LX SFP (01KN829) | 1000BASE-LX | 1310 nm 9 µ SMF cable up to 10 km. | LC |
1 GbE RJ-45 SFP (01KN833) | 1000BASE-T | UTP Category 5, 5E, or 6 up to 100 meters. | RJ-45 |
Management ports | |||
10/100/1000 Mb Ethernet port | 1000BASE-T |
Up to 25 m with UTP cables supplied by Lenovo (see Table 4). UTP Category 5, 5E, or 6 up to 100 meters. |
RJ-45 |
Serial port | RS-232 | DB-9/RJ-45-to-RJ-45 console cable (comes with the director). | RJ-45 |
Firmware
For details on the latest features supported with the X7-4 & X7-8 FC SAN Directors, see the Administration Guide for the latest available Fabric OS version 9.0 and above:
https://www.broadcom.com/products/fibre-channel-networking/software/fabric-operating-system
Inter-Chassis Links
UltraScale Inter-Chassis Link (ICL) are optional features for the X7 Directors. ICLs allow the interconnect of up to 9 (full-mesh) or 12 (core-edge) X7-4 or X7-8, or a combination of both, or to connect to X6-4 (Lenovo DB400D) or X6-8 (Lenovo DB800D) Backbones by using the QSFP+ ports on the core routing blades.
The following table lists ordering information for the optional features and bundles for the X7-4 and X7-8 FC SAN Directors Models HC1.
Each Inter-Chassis Link (ICL) bundle includes Port on Demand (POD) licenses to activate four available QSFP+ ports on both CR blades in the chassis. On the X7-8 clients can are required to have a minimum of 2 licenses and can upgrade to 3 or the max of 4 licenses per chassis.
Each ICL bundle also includes eight QSFP+ transceivers to populate the activated ports.
Management software
Lenovo offers optional Brocade SANnav™ Management Portal and SANnav Global View software license subscriptions that provide comprehensive visibility into the SAN environment, allow administrators to quickly identify, isolate, and correct problems, and accelerate administrative tasks by simplifying and automating workflows.
SANnav Management Portal is a next-generation SAN management application with a simple browser-based user interface (UI) and with a focus on streamlining common workflows, such as configuration, zoning, deployment, monitoring, troubleshooting, reporting, and analytics.
Lenovo offers the following SANnav Management Portal subscriptions:
- SANnav Management Portal Base: Designed for mid-sized SANs to manage up to 600 SAN switch ports only (SAN director ports can only be managed with the Enterprise edition).
- SANnav Management Portal Enterprise: Designed for enterprise-class SANs to manage up to 15 000 SAN switch and director ports.
SANnav Management Portal supports all Brocade SAN switches and platforms that run the Fabric OS® version 7.4 or above, including Lenovo B300, B6505, B6510, DB610S, DB620S, DB400D, DB720S, DB730S, DB800D, Brocade Directors, and FC5022.
With SANnav Global View, administrators can quickly visualize the health, performance, and inventory of multiple SANnav Management Portal instances using a simple, intelligent dashboard and can easily navigate from a global view down to local environments to investigate points of interest. SANnav Global View is designed to manage up to 20 SANnav Management Portal instances.
For more information, refer to the SANnav Management Portal documentation:
http://www.broadcom.com/products/fibre-channel-networking/software/sannav-management-portal#documentation
The following table lists ordering information for the optional SANnav Management Portal and SANnav Global View management tools. After a client has an active SANnav license, Lenovo offers a “license extension/renewal”. This offering provides our clients the flexible to extend their subscription down to a specific end date. This allows clients the ability to align to your company’s budget or align with warranty of your FC SAN switches/directors. Please engage directly with your Lenovo sales representative for more details.
The SANnav licenses are subscription-based with 1-year, 3-year, or 5-year software entitlement and support.
Fibre Channel standards
The SAN Directors supports the standards listed at the following web page:
https://www.broadcom.com/support/fibre-channel-networking/san-standards/standards-compliance
Ethernet standards
The X7 Directors support the following Ethernet standards:
- IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX)
- IEEE 802.1p Class of Service (CoS) prioritization
- IEEE 802.1Q VLAN Tagging
- IEEE 802.1Qbb Priority-Based Flow Control (PFC)
- IEEE 802.1Qaz Enhanced Transmission Selection (ETS)
- IEEE 802.3 10BASE-T Ethernet (CP management interfaces)
- IEEE 802.3u 100BASE-TX Fast Ethernet (CP management interfaces)
- IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
- IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet
- IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet
- IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
- IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
- IEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb Ethernet
- IEEE 802.3ba 40GBASE-LR4 long range fiber optics 40 Gb Ethernet
- IEEE 802.3bm 40GBASE-ER4 extended range fiber optics 40 Gb Ethernet
- IEEE 802.3bm 100GBASE-SR4 short range fiber optics 100 Gb Ethernet
- 10GBASE-ZRD DWDM fiber optics 10 Gb Ethernet
Cooling
Models of the X7 Directors do not include cooling modules (fan assemblies) - the cooling modules must be ordered as well. Each cooling module has two integrated fans.
Two matching cooling modules are required for the X7-4, and three cooling modules are required for the X7-8. Cooling modules provide N+1 fan redundancy (3+1 for the X7-4; 5+1 for the X7-8), and the device can continue operation while one fan assembly is replaced if the fan assembly is replaced immediately.
Air flow: It is also important to remember your fan tray airflow must match your power supplies!
The following table lists the supported cooling modules.
Power supplies and cables
Models of the X7 Directors do not include power supplies - the power supplies must be ordered separately.
Power supply requirements:
- X7-8: Four matching PSUs must be installed to provide power efficiency and 2+2 redundancy.
- X7-4: Two matching PSUs must be installed to provide power efficiency and 1+1 redundancy
The AC power supplies are hot-swap 1450 W (100-120 V AC) / 2870 W (200-240 V AC), and each power supply has an IEC 320-C20 connector. Each power supply has two integrated fans that provide non-port side air intake that matches the airflow of the cooling modules.
The High Voltage (HV) Power Supplies has a HVAC/HVDC power cable receptacle connector. The unique power cords is available from Lenovo and is 6m (19.7 ft.) long and contain three colored 14 AWG unterminated wires.
The following table lists the supported power supplies.
The X7 Directors do not include power cords by default. Up to four rack power cables or line cords should be ordered for the FC SAN Directors depending on the quantity of power supplies.
The following table lists the available power cords.
Rack installation
The X7 Directors come standard with the adjustable 27" to 31" rack mount kits that can be used for 4-post rack installations. The X7-4 also comes standard with the 27” to 31” Airflow Diversion Kit that allow to divert the airflow from the side air vent to the port side. In addition, the X7-8 supports 22" rack mount kit for specific racks and the X7-4 offers an optional 18”to 24” Airflow Diversion Kit.
If required, the Brocade FC SAN Directors can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kits.
The following table lists rack-mount options.
The optional airflow diversion kit for the X7-4 Director is shown in the following figure.
The optional mid-mount rack kits for the X7-4 and X7-8 Directors are shown in the following figure.
Figure 10. X7-4 (left) and X7-8 (right) Mid-mount Rack Kits
In addition, in order for the X7-4 and X7-8 FC SAN Directors to meet FIPS 140-2 Level 2 Physical Security requirements the tamper-evident seals must be installed (see the following table for ordering information).
Physical specifications
The X7 Directors have the following dimensions and weight:
Dimensions:
- X7-8 Director
- Height: 61.23 cm (24.11 in., 14U)
- Width: 43.74 cm (17.23 in.)
- Depth: 61.04 cm (24.04 in.)
- X7-4 Director
- Height: 34.45 cm (13.56 in., 8U)
- Width: 43.74 cm (17.23 in.)
- Depth: 61.04 cm (24.04 in.)
- X7-4 with airflow diversion rack-mount kit
- Height: 40.00 cm (15.75 in., 9U)
- Width: 43.74 cm (17.23 in.)
- Depth: 61.29 cm (24.09 in.)
Weight:
- X7-8 Director
- 61 kg (78.5 lb) for chassis
- 8 kg (321.5 lb) maximum fully populated configuration
- X7-4 Director
- 5 kg (54 lb) for chassis
- 68.95 kg (152.0 lb) maximum fully populated configuration
Operating environment
Temperature and humidity, Electrical requirements, and Heat output Information can be found in the Brocade X7-4 and X7-8 Director Hardware Installation Guide. https://www.broadcom.com/roducts/fibre-channel-networking/directors/x7-directors
Warranty upgrades and post-warranty support
The X7 Directors have a three-year warranty.
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG File Migration Services
Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Lenovo TruScale
Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.
Lenovo TruScale is the unified solution that gives you simplified access to:
- The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
- A single-contract framework for full visibility and accountability
- The global scale to rapidly and securely build teams from anywhere
- Flexible fixed and metered pay-as-you-go models with minimal upfront cost
- The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.
For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Regulatory compliance
The X7 Directors conform to the following regulations which can be found in the Hardware Installation Guide, available from the following web page:
https://www.broadcom.com/products/fibre-channel-networking/directors/x7-directors
Interoperability
For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.
External storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo that can be used in Lenovo FC SAN solutions.
Note: Information provided in this section is for ordering reference purposes only. End-to-end LTO Ultrium configuration support for a particular tape backup unit must be verified through the System Storage Interoperation Center (SSIC):
http://www.ibm.com/systems/support/storage/ssic
For more information, see the list of Product Guides in the Tape Autoloaders and Libraries category:
https://lenovopress.com/storage/tape/library
Rack cabinets
The following table lists the supported rack cabinets.
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Seller training courses
The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.
-
Family Portfolio: Storage Networking
2024-10-14 | 15 minutes | Employees and Partners
DetailsFamily Portfolio: Storage NetworkingThis course will provide you an overview of the Storage Networking family. After completing this course, you should be able to identify the products in the Storage Networking portfolio and their features, describe product family benefits, and recognize when a specific product should be used.
Published: 2024-10-14
Length: 15 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Lenovo Data Center Product Portfolio
2024-05-29 | 20 minutes | Employees and Partners
DetailsLenovo Data Center Product PortfolioThis course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.
Published: 2024-05-29
Length: 20 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Selling and Configuring Gen 7 Fibre Channel Directors
2023-11-03 | 25 minutes | Employees and Partners
DetailsSelling and Configuring Gen 7 Fibre Channel DirectorsIn this course we will be discussing what Lenovo’s Gen 7 portfolio of offerings and specifically dive into a deeper understanding on how and where to position Gen 7 Directors. We will review how clients are likely to use Directors, plus look at all the different components that go into a director and the decisions required to help build a valid configuration.
Published: 2023-11-03
Another objective will be to make sure you can communicate high level some of the benefits of directors and also the advantage of Gen 7 Directors.
Course objectives:
1. Understand Lenovo’s full Gen 7 Fibre Channel product portfolio
2. Understand how and where to position Gen 7 Directors
3. Communicate the benefits to your clients
4. Help clients build Director configurations based on their requirements
Length: 25 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Related publications and links
For more information, see the following resources:
- Lenovo FC SAN Switches product page:
https://www3.lenovo.com/us/en/data-center/storage/storage-area-network/fibre-channel-switches/c/san-fibre-channel-switches - Brocade X7-4 and X7-8 FC Director product publications:
https://www.broadcom.com/products/fibre-channel-networking/directors/x7-directors- Hardware Installation Guide
- Fabric OS Administration Guide
- Fabric OS Extension Configuration Guide
- Fabric OS Command Reference
- Fabric OS Message Reference
- Fabric OS MIB Reference
- Flow Vision Configuration Guide
- FOS and SANnav Downloads - https://support.lenovo.com/us/en/solutions/TT116
- TruFOS Certificates - https://support.lenovo.com/us/en/solutions/TT1149
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®
The following terms are trademarks of other companies:
UltraScale+™ and UltraScale™ are trademarks of Advanced Micro Devices, Inc.
Microsoft® and Excel® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the September 9, 2024 update:
- The following were updated with correct PNs and FC Transceivers and cables section:
- Brocade Secure 64-Gb SWL SFP-DD Transceiver, 4M27A65427
- Brocade Secure 64-Gb SWL SFP-DD Transceiver 8-pack, 4M27A65428
Changes in the November 10, 2023 update:
- The following model has been withdrawn from marketing - Blades section:
- Gen 6 Port Blade FC32-64, with 8 x 128Gb (4x32Gb) SWL QSFP optics, B26X, 4M27A09985
- The following options have been withdrawn from marketing - Transceivers and cables section:
- Brocade 4x16Gb FC-Compliant SWL QSFP+, AVGH, 01KN805
- Brocade 40Gb QSFP+ SR4 FCoE, BiDi, B26V, 4M27A09988
- Brocade 40Gb (4x10GbE) QSFP+ SR4 FCoE, B26U, 4M27A09987
- Brocade 100Gb (4x25GbE) QSFP28 SR4 FCoE, B26W, 4M27A09989
Changes in the July 11, 2023 update:
- Added new FC64-64 port blade and features - updated sections:
- Key features
- Components and connectors
- System specifications
- Transceivers and cables
- Operating environment
Changes in the April 17, 2023 update:
- Updated transceiver data - Blades section
First published: March 28, 2023.
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The author of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at [email protected].