skip to main content

Brocade X7-8 and X7-4 FC SAN Directors

Product Guide

Home
Top

Abstract

The Brocade X7 FC SAN Directors are high-performance, modular, chassis-based Fibre Channel networking devices that provides connectivity between servers, switches and storage systems to form the backbone of an enterprise FC storage area network. The X7 Directors provide up to 384 64Gb ports or up to 512 32Gb ports, enabling organizations to scale more devices, applications, and workloads.

This product guide provides essential pre-sales information to understand the X7 Directors, their key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the X7 Directors and consider their use in IT solutions.

 

Change History

Changes in the September 9, 2024 update:

  • The following were updated with correct PNs and FC Transceivers and cables section:
    • Brocade Secure 64-Gb SWL SFP-DD Transceiver, 4M27A65427
    • Brocade Secure 64-Gb SWL SFP-DD Transceiver 8-pack, 4M27A65428

Introduction

The Brocade X7 FC SAN Directors are high-performance, modular, chassis-based Fibre Channel networking devices that provides connectivity between servers, switches and storage systems to form the backbone of an enterprise FC storage area network. The X7 Directors provide a modular building block, purpose-built for scalability to accommodate growth and power large-scale storage environments.

With a 50% latency reduction compared to the previous generation, X7 Directors maximize the performance of NVMe storage and high transaction workloads, eliminating I/O bottlenecks and unleashing the full performance of next generation storage.

The modular design provides flexibility with two customizable chassis that can scale on-demand for more devices, applications, and workloads, the X7-8 and X7-4. Both chassis utilize Brocade UltraScale ICL technology to scale out modular SANs while preserving blade ports for device connectivity and allowing flexible SAN design that supports core-edge or mesh topologies.

Brocade Gen 7 Director X7-8 (left) and X7-4 (right)
Figure 1. Brocade Gen 7 Director X7-8 (left) and X7-4 (right)

Did you know?

X7 Directors provide cyber resiliency with integrated security technology that protects mission critical operations by validating the integrity of Gen 7 hardware and software. With enhanced security and autonomous SAN technology, organizations can take the guesswork out of protecting and managing a network.

With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that offers "one stop shop" and single point of contact for delivery of leading-edge technologies and innovations from Lenovo and other leading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs, including end-user devices, servers, storage, networking, services, management software, and financing.

Key features

The Brocade X7 FC SAN Directors provide up to 512 ports, enabling organizations to scale more devices, applications, and workloads. With diverse deployment options, multiprotocol flexibility, and mixed blade capability, organizations can adapt and optimize their businesses to meet next-generation storage and server requirements. The X7 Directors support the concurrent use of both traditional Fibre Channel and NVMe storage traffic, allowing organizations to seamlessly integrate Gen 7 Fibre Channel networks with next generation NVMe-based storage, without a disruptive rip-and-replace.

The X7 Directors lay the foundation for the autonomous SAN. With autonomous SAN technology, the director harnesses the power of analytics and the simplicity of automation to optimize performance, ensure reliability, and simplify management. Leveraging these capabilities enables organizations to realize a self-learning, self-optimizing, and self-healing SAN.

The X7 Directors offer the following features and benefits:

  • Scale more devices, applications, and workloads with up to 512 64 Gb links per chassis
  • Maximize NVMe and high transaction workloads with 50% lower network latency
  • Transform telemetry data into actionable insights to optimize performance and ensure reliability
  • Automate actions to simplify management and resolve issues without intervention
  • Increase visibility and simplify operations with a modern SAN management tool
  • Safeguard mission-critical workloads from vulnerabilities with Gen 7 integrated security
  • Seamlessly integrate next generation NVMe into the storage fabric without a disruptive rip-and replace
  • Design flexible architectures to increase agility with concurrent Fibre Channel, NVMe, FICON, or FCIP connectivity
  • Extend replication over distance with a highly scalable extension solution for Fibre Channel, IP, and FICON
  • Enterprise bundle software (Fabric Vision, Extended Fabrics, Trunking, CUP and Integrated Routing) are included as standard features.

Components and connectors

The Brocade X7-4 Director with the airflow diversion kit is a 9U rack mount chassis that is built for midsize networks. It has four horizontal blade slots to provide up to 256 ports for device connectivity. An additional 16 UltraScale ICL connections provide 64 ports for chassis-to-chassis interconnect.

The Brocade X7-8 Director is a 14U rack mount chassis that is built for large enterprise networks. It has eight vertical blade slots to provide up to 512 ports for device connectivity. An additional 32 UltraScale Inter-Chassis Link (ICL) connections provide 128 ports for chassis-to-chassis interconnect.

In this section:

X7-4 Chassis

The following figure shows the port-side view of the X7-4 FC SAN Director.

X7-4 FC SAN Director port-side view
Figure 2. X7-4 FC SAN Director port-side view

The port side of the X7-4 chassis has the following components:

  • Four blade slots within the X7-4 chassis can be populated with optional port or extension blades. The chassis comes without port blades or extension blades, see Blades for ordering information.
  • Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis). A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:
    • USB port for firmware download and technical support data
    • Serial console RJ-45 port
    • 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
    • 10/100/1000 Mb Ethernet RJ-45 port for service
    • 10 Gb Ethernet RJ-45 port (reserved for future use)
    • Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.
  • Two redundant hot-swap active/active Core Routing blades (CR blades come with the chassis). Core routing blades contain ASICs that allow switching between up to four port blades, and each core routing blade provides 96 Fibre Channel backplane ports for port or extension blade connections and 32 front-end FC links that are mapped to 8 QSFP+ ports for inter-chassis links (ICLs). POD License Kits are sold separately.

The following figure shows the non-port side view of the X7-4 FC SAN Director.

X7-4 FC SAN Director non-port side view
Figure 3. X7-4 FC SAN Director non-port side view

The non-port side of the X7-4 chassis has the following components:

  • Choice of hot-swap power supplies AC or High Voltage (two must be ordered together with the chassis). Dual-function high-voltage AC, high-voltage DC (HVAC/HVDC) power supply assembly: Converts AC or DC input to the required DC output power required for device operation. Each power supply assembly provides the following power outputs in Watts at the indicated AC and DC input rated voltages: 1450W (100–120 VAC); 2870W (200–277 VAC); 2870W (240–380 VDC). Most common is AC NPI power supply.
    • AC power supply supporting non-port side air intake (NPI) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the non-port side to the port side of the device.
    • AC power supply model supporting non-port side air exhaust (NPE) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the port side to the non-port side of the device.
    • High voltage power supply model supporting non-port side air intake (NPI). This assembly has two fans that move the air from the non-port side to the port side of the device.
    • High voltage power supply model supporting non-port side air exhaust (NPE). This assembly has two fans that move the air from the port side to the non-port side of the device.
  • Choice of hot-swap cooling modules (two must be ordered together with the chassis and must match airflow of the power supplies)
    • Non-port side air intake (NPI) moves the air from the non-port side to the port side of the device.
    • Non-port side air exhaust (NPE) moves the air from the port side to the non-port side of the device.

X7-8 Chassis

The following figure shows the port-side view of the X7-8 FC SAN Director.

X7-8 FC SAN Director port-side view
Figure 4. X7-8 FC SAN Director port-side view

The port side of the X7-8 chassis has the following components:

  • Eight blade slots within the X7-8 chassis can be populated with optional port or extension blades. The chassis comes without port blades or extension blades, see Blades for ordering information.
  • Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis) A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:
    • USB port for firmware download and technical support data
    • Serial console RJ-45 port
    • 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
    • 10/100/1000 Mb Ethernet RJ-45 port for service
    • 10 Gb Ethernet RJ-45 port (reserved for future use)
    • Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.
  • Two redundant hot-swap active/active Core Routing blades (CR blades come with the chassis). Core routing blades contain ASICs that allow switching between up to eight port blades, and each core routing blade provides 192 Fibre Channel backplane ports for port or extension blade connections and 64 front-end FC links that are mapped to 16 QSFP+ ports for inter-chassis links (ICLs). POD License Kits are sold separately.

The following figure shows the non-port side view of the X7-8 FC SAN Director.

X7-8 FC SAN Director non-port side view
Figure 5. X7-8 FC SAN Director non-port side view

  • Choice of hot-swap power supplies AC or High Voltage (four must be ordered together with the chassis). Dual-function high-voltage AC, high-voltage DC (HVAC/HVDC) power supply assembly: Converts AC or DC input to the required DC output power required for device operation. Each power supply assembly provides the following power outputs in Watts at the indicated AC and DC input rated voltages: 1450W (100–120 VAC); 2870W (200–277 VAC); 2870W (240–380 VDC). Most common is AC NPI power supply.
    • AC power supply supporting non-port side air intake (NPI) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the non-port side to the port side of the device.
    • AC power supply model supporting non-port side air exhaust (NPE) provides 1450W (100–120 VAC) and 2870W (200–240 VAC). This assembly has two fans that move the air from the port side to the non-port side of the device.
    • High voltage power supply model supporting non-port side air intake (NPI). This assembly has two fans that move the air from the non-port side to the port side of the device.
    • High voltage power supply model supporting non-port side air exhaust (NPE). This assembly has two fans that move the air from the port side to the non-port side of the device.
  • Choice of hot-swap cooling modules (three must be ordered together with the chassis and must match airflow of the power supplies)
    • Non-port side air intake (NPI) moves the air from the non-port side to the port side of the device.
    • Non-port side air exhaust (NPE) moves the air from the port side to the non-port side of the device

Port Blades and SX6 Extension Blades

The following figure shows the FC64-64 port blade.

FC64-64 port blade

Figure 6. FC64-64 port blade
 

The Brocade FC64-64 Fibre Channel port blade with 32 SFP-DD ports provides 64 x 64G Fibre Channel ports with backward-compatibility support for 8, 16, and 32G Fibre Channel connectivity. The FC64-64 port blade enables industry-leading platform density for Gen 7 SAN configurations supporting up to 256 64-Gbps external ports in a single X7-4 chassis, and up to 512 64-Gbps external ports in a single X7-8 chassis. Leveraging this efficient, high-density designed blade, organizations can consolidate more device connectivity into a single fabric and reduce capital expenses by consuming less rack space. By utilizing fewer chassis, it lowers operational cost by reducing power consumption, cooling, and management. With industry-leading port density and increased bandwidth, organizations can effectively scale to meet data growth demands and drive efficiency by maximizing space utilization with room for future scaling of demanding IT applications. (Requires chassis use FOS 9.2 or later).

The following figure shows the 48-port blade.

FC32-48 port blade
Figure 7. 48-port blade (Image example is FC32-48)

There are multiple 48-port blades offerings. These blades contain 48 ports capable of Fibre Channel speeds up to 32 or 64 Gbps depending on model, and support up to 192 32-Gbps external ports in a single X7-4 chassis, and up to 384 32-Gbps external ports in a single X7-8 chassis. While most client will leverage SWL transceiver models, LWL models are available for those mainframe-connected environments or those needing connectivity over longer distances.

  • The Gen 7 Brocade FC64-48 Fibre Channel port blade provides 48 x 64G Fibre Channel ports with backward-compatibility support for 8, 10, 16, and 32G Fibre Channel connectivity.
  • The Brocade FC32-X7-48 Fibre Channel port blade provides 48 x 32G Fibre Channel ports with backward-compatibility support for 8, 10, and 16G Fibre Channel connectivity.
  • The Gen 6 FC32-48 Fibre Channel port blade provides 48 x 32G Fibre Channel ports with backward-compatibility support for 4, 8, 10, and 16G Fibre Channel connectivity

The following figure shows the SX6 extension blade.

SX6 extension blade
Figure 8. SX6 extension blade

The SX6 Extension blade is intended as an extension platform to support Fibre Channel, FICON, and IP based storage data flows. Extension features enable you to use the existing IP wide area network (WAN) infrastructure to connect Fibre Channel and IP fabrics. Extension features support applications such as remote data replication (RDR), centralized backup, and data migration over very long distances. Extension tunnels, built on a physical connection between two extension switches or blades, allow Fibre Channel and IP I/O to pass through the IP WAN. The SX6 Extension blade can connect with an SX6 blade in another Brocade FC SAN Director or with a Brocade 7840 Extension Switch.

System specifications

The following table lists the Brocade X7-4 and X7-8 FC SAN Director system specifications.

Note: The supported hardware options and firmware features listed in this product guide are based on the Fabric OS version 9.X.

Table 1. Specifications
Component Specification
System Architecture
Chassis

Brocade X7-8: Non-blocking architecture

  • X7-8 Director with 48x 64Gb/s port blades: 30.9Tb/s of aggregate chassis bandwidth (384 device ports with a 64Gb/s data rate plus 32 4xGen7 ICLs)
  • X7-8 Director with 64 64G port blades: 39.6Tb/s of aggregate chassis bandwidth (512 device ports with a 64G data rate plus 32 4xGen7 ICLs)

Brocade X7-4: Non-blocking architecture

  • X7-4 Director with 48x 64Gb/s port blades: 15.7Tb/s of aggregate chassis bandwidth (192 device ports with a 64Gb/s data rate plus 16 4xGen7 ICLs)
  • X7-4 Director with 48 64Gport blades: 19.8Tb/s of aggregate chassis bandwidth (192 device ports with a 64G data rate plus 16 4xGen7 ICLs)

Each provides support for (E, F, D, M, SIM, and EX) Fibre Channel ports using 48-port 64Gb/s Fibre Channel blades.

Control processor Redundant (active/standby) control processor modules.
Scalability Full-fabric architecture of 239 switches.
Certified maximum 6000 active devices per switch; 56 switches, 19 hops in Brocade Fabric OS® (FOS) fabrics; larger fabrics certified as required.
Fibre Channel blades
  • Brocade FC64-48 port blade provides 48 ports of 64Gb/s Fibre Channel.
  • Brocade FC64-64 port blade provides 64 ports of 64Gb/s Fibre Channel.
  • Brocade FC32-X7-48 port blade provides 48 ports of 32Gb/s Fibre Channel.
  • Brocade FC32-48 port blade provides 48 ports of 32Gb/s Fibre Channel.
  • Brocade FC32-64 port blade provides 64 ports of 32Gb/s Fibre Channel.
Extension blades Brocade SX6 Extension Blade provides Fibre Channel extension (16x 32Gb/s Fibre Channel ports) and IP extension over IP networks (16×1GbE/10GbE and 2×40GbE ports).
Performance

Brocade FC64-48 Port Blade:

  • Fibre Channel: 8.5Gb/s line speed, full duplex; 10.53Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex; 57.8Gb/s line speed, full duplex.
  • Autosensing of 8, 16, 32, and 64Gb/s port speeds depending on SFPs used.
  • 10Gb/s port speeds with dedicated SFPs.

Brocade FC64-64 Port Blade:

  • Fibre Channel: 8.5Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex; 57.8Gb/s line speed, full duplex.
  • Autosensing of 8, 16, 32, and 64G port speeds depending on SFP-DD/SFP+ used. Support for 8G requires a 32G SFP+ LWL or ELWL transceiver.

Brocade FC32-X7-48 Port Blade:

  • Fibre Channel: 4.25Gb/s line speed, full duplex; 8.5Gb/s line speed, full duplex; 10.53Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex.
  • Autosensing of 4, 8, 16, and 32Gb/s port speeds depending on SFPs used.
  • 10Gb/s port speeds with dedicated SFPs.

Brocade FC32-48 Port Blade:

  • Fibre Channel: 4.25Gb/s line speed, full duplex; 8.5Gb/s line speed, full duplex; 10.53Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex.
  • Autosensing of 4, 8, 16, and 32G port speeds depending on SFPs used.
  • 10G port speeds with dedicated SFPs.

Brocade FC32-64 Port Blade:

  • Fibre Channel: 4.25Gb/s line speed, full duplex; 8.5Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex.
  • Autosensing of 4, 8, 16, and 32Gb/s port speeds depending on QSFPs used.
  • FCoE: 10GbE, 25GbE, or 40GbE FCoE speeds.
  • Support for 10GbE, 25GbE, and 40GbE speeds requires the use of the appropriate QSFP transceiver.
ISL Trunking

Frame-based trunking with up to eight 64Gb/s ports per ISL trunk; up to 512Gb/s per ISL trunk between switches using 8G, 16G, 32G, or 64G ports; exchange-based load balancing across ISLs with DPS included in Brocade FOS.

UltraScale ICL Trunking

Chassis-to-chassis linkage through connectors on the Core Routing (CR) blade. Can configure the following maximum number of QSFPs per trunk depending on blade type, connecting:

  • Up to four QSFP ports in a trunk group between two Brocade CR64-4 blades. For trunks that contain four or fewer QSFP ports, ports in a trunk must be in the same port group on each blade.
  • Up to four QSFP ports in a trunk group between a Brocade CR64-4 blade and a CR64-8 blade. For trunks that contain four or fewer QSFP ports, ports in a trunk must be in the same port group on each blade.

A minimum of two QSFP connections are required for a trunk, and up to four QSFP trunks between pairs of Brocade CR64-8 or CR64-4.

Multi-chassis with UltraScale ICL ports Up to 4608 Fibre Channel ports; UltraScale ICL ports (32 for 8-slot or 16 per 4-slot chassis, optical QSFP) connect up to 9 chassis in a full-mesh topology or up to 12 chassis in a core-edge topology.
Chassis bandwidth
  • X7-8: 39.6Tb/s per chassis with 512 device ports + 32 UltraScale ICL connections supporting 128 ports.
  • X7-4: 19.8Tb/s per chassis with 256 device ports + 16 UltraScale ICL connections supporting 64 ports.
Slot bandwidth 3072Gb/s (line rate) providing line-rate performance for the Brocade FC64-48 blade or 4096Gb/s providing line-rate performance for the Brocade FC64-64 blade.
Maximum frame size 2112-byte payload.
Frame buffers 24,000 per switching ASIC.
Classes of service Class 2, Class 3, Class F (inter-switch frames).
Fibre Channel port types
  • CR64-8 and CR64-4 CR blades: E_Port, EX_Port, and D_Port.
  • FC64-64, FC64-48, FC32-X7-48, FC32-48, FC32-64 port blades: F_Port, E_Port, EX_Port, M_Port, SIM, and D_Port.
  • SX6 extension blade: F_Port, FL_Port, E_Port, SIM, and EX_Port on FC and VE_Port on GbE.

Self-discovery is based on switch type (U_Port) with an optional port type control.

Data traffic types Fabric switches supporting unicast.
Media types
  • Brocade FC64-48 port blade:
    • 64G FC SFP+ LC connector: SWL, LWL, ELWL
    • 32G FC SFP+ LC connector: SWL, LWL, ELWL
    • 10G FC SFP+ LC connector: SWL, LWL
  • Brocade FC64-64 port blade:
    • 64G FC SFP-DD LC connector: SWL
    • 64G FC SFP+ LC connector: SWL, LWL
    • 32G FC SFP+ LC connector: LWL, ELWL
  • Brocade FC32-X7-48 and FC 32-48 port blade:
    • 32G FC SFP+ LC connector: SWL, LWL, ELWL
    • 16G FC SFP+ LC connector: SWL, LWL, ELWL
    • 10G FC SFP+ LC connector: SWL, LWL
  • Brocade FC32-64 port blade:
    • 4x32G FC QSFP+ MPO connector: SWL
    • 4x32G FC QSFP+ SMF LC connector: 2 km (fixed at 4x32G only)
    • 4x16G FC QSFP+ MPO connector: SWL
    • FCoE QSFP+ MPO connector: 100GBASE-SR4, 4x25GbE
    • FCoE QSFP+ MPO connector: 40GBASE-SR4, 4x10GbE
    • FCoE QSFP+ LC connector: 40GbE BiDi
  • Brocade SX6 Extension Blade:
    • 32G FC SFP+ LC connector: SWL, LWL, ELWL
    • 16G FC SFP+ LC connector: SWL, LWL, ELWL
    • 10G FC SFP+ LC connector: SWL, LWL
    • Ethernet QSFP+ MPO connector: 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4
    • Ethernet QSFP+ LC connector: 40GbE BiDi
    • 10GbE SFP+ LC connector: SR, LR
    • 1GbE SFP+ LC connector: SX, LX
    • 1GbE SFP+ copper connector
  • Core Routing (CR) blades, Brocade CR64-4 and CR64-8:
    • Gen 7 FC QSFP+ MPO connector: SWL, 2 km*
    • 4x32G FC QSFP+ SMF LC connector: SWL, 2 km

* Use of the Gen 7 2-km ICL QSFP is subject to the following environmental ratings for maximum intake air temperature: 0–40°C at sea level; 0–35°C up to 1500m (4921 ft) elevation; and 0–30°C from 1500m to 3000m (9843 ft) elevation.

USB One USB port per control processor for firmware download, SupportSave, and configuration upload or download.
Fabric services BB Credit Recovery; Brocade Advanced Zoning (Default Zoning, Port/WWN Zoning, Peer Zoning); Congestion Signaling; Dynamic Path Selection (DPS); Extended Fabrics; Fabric Performance Impact Notification (FPIN); Fabric Vision; FDMI; FICON CUP; Flow Vision; F_Port Trunking; FSPF; Integrated Routing; ISL Trunking; Management Server; NPIV; NTP v3; Port Decommission/Fencing; QoS; Registered State Change Notification (RSCN); Name Server; Target-Driven Zoning; Traffic Optimizer; Virtual Fabrics (Logical Switch, Logical Fabric); VMID+ and AppServer.
Extension Supports DWDM, CWDM, and FC-SONET Devices; Fibre Channel; In-flight Compression (Brocade LZO) and Encryption (AES-GCM-256); BB Credit Recovery; FCIP; IP Extension; Adaptive Rate Limiting (ARL); Data Compression; Fast Write; Read/Write Tape Pipelining; QoS.
FICON

FICON cascading; support for lossless DLS; FICON CUP; Advanced Accelerator for FICON (IBM z/OS Global Mirror and read/write Tape Pipelining). (FICON connectivity is not supported on the FC32-64 or FC64-64 blades.)

System Components
Fibre Channel ports
  • Brocade X7-8: Up to 512 ports, universal (E_Port, F_Port, EX_Port, M_Port, D_Port, SIM Port, *FICON).
  • Brocade X7-4: Up to 256 ports, universal (F_Port, E_Port, EX_Port, M_Port, D_Port, SIM Port, *FICON).

*Brocade 48 port blade required

Classes of service Class 2, Class 3, Class F (inter-switch frames).
ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signaling Interface standard).
Port-to-port latency
  • Local switching: 460 ns at 64Gb/s (including FEC as part of the FC standard). 
  • Blade-to-blade: 1.4 μs.
High Availability
Architecture Non-blocking shared memory; passive backplane; redundant active/passive control processor; redundant active/active core switching blades; redundant WWN cards.
Chassis power
  • Brocade X7-8: 2+2 redundancy.
  • Brocade X7-4: 1+1 redundancy.
Cooling

Brocade X7-8:  

  • Requires three fan tray assemblies. A failure condition is one failed fan from any fan tray.
  • Each assembly contains two fans for a total of six fans. The system requires five of six functioning fans for operation in the Brocade X7-8. One fan tray assembly can be hot-swapped and should be replaced immediately in the event of a failure.

Brocade X7-4:

  • Requires two fan tray assemblies. A failure condition is one failed fan from any fan tray.
  • Each assembly contains two fans for a total of four fans. The system requires three of four functioning fans for operation in the Brocade X7-4. One fan assembly can be hot-swapped and should be replaced immediately in the event of a failure.
Solution availability Designed to provide 99.999% uptime capabilities; hot-pluggable redundant power supplies, fans, WWN cards, processors, core switching, port blades, and optics; online diagnostics; non-disruptive firmware download and activation.
Management
Management

Brocade Advanced Web Tools; Brocade SANnav Management Portal and SANnav Global View; Command Line Interface (CLI); HTTP/HTTPS; RESTful API; SSH; SNMP v1/v3 (FE MIB, FC Management MIB); trial licenses for add-on capabilities.

Security AES-GCM-256 encryption on FC ISLs (E_Port); Device Connection Control (DCC); DH-CHAP (between switches and end devices); Fabric Configuration Server (FCS); FCAP switch authentication; FIPS 140-2 compliant; HTTPS; IP filtering; LDAP with IPv6; OpenLDAP; RADIUS; user-defined Role-Based Access Control (RBAC); Secure Boot; Secure Copy (SCP); SFTP; SSH v2; Switch Binding; TACACS+; TLS v1.2/v1.3; USGv6 compliant.
Management access 10/100/1000Mb/s Ethernet (RJ-45) per control processor; serial console port (RJ-45) and one USB per control processor module; DHCP/DHCPv6; call-home integration enabled through Brocade SANnav Management Portal.
Diagnostics Active Support Connectivity (ASC) and Brocade Support Link (BSL); built-in flow generator; ClearLink® optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; Fabric Performance Impact Monitoring (FPI); flow mirroring; Forward Error Correction; frame viewer; IO Insight for SCSI and NVMe monitoring; Monitoring and Alerting Policy Suite (MAPS); nondisruptive daemon restart; optics health monitoring; POST and embedded online/offline diagnostics, including environmental monitoring, FCping, and Pathinfo (FC traceroute); power monitoring; RAStrace logging; Rolling Reboot Detection (RRD); Syslog/Audit Log; VM Insight.
Warranty & Support
Hardware warranty & SW entitlement Three-year customer-replaceable unit limited warranty with 9x5 next business day parts delivered. Also, entitlement to access latest FOS software
Service and support Optional service upgrades are available through Lenovo Services: 9x5 next business day onsite response, 24x7 2-hour or 4-hour onsite response, 24x7 6-hour or 24-hour committed service repair, up to 5 years of warranty coverage, and 1-year or 2-year post-warranty extensions.

Models

The following table lists the X7-4 and X7-8 FC SAN Director Models.

Table 2. Models
Part number Description
7DB4CTO1WW Brocade X7-4 FC Director (4 Blade slots, 9U, 3-year warranty/entitlement)
7DB4CTO2WW Brocade X7-8 FC Director (8 Blade slots, 14U, 3-year warranty/entitlement)

The X7-4 and X7-8 FC SAN Director part numbers include the following items:

  • One Director chassis that contains the following components:
    • Two control processing blades
    • Two core routing blades
  • Enterprise Bundle SW license installed
  • Integrated Routing SW license installed
  • Ground lug kit
  • Wrist strap
  • X7-4 Specific
    • Vertical Cable Management Comb
    • Airflow diversion Kit (27"-31") and documentation
    • 4-post rack mount Kit
  • X7-8 Specific
    • Cable Management Comb
    • 14U rack mount kit (27"-31")

Configuration notes:

  • Models come standard with CR blades, however in order to leverage the ICLs, ICL POD kits are required. See the Inter-Chassis Links section for details.
  • Models do not include port blades or extension blades and will need to be ordered for the Director model. See the Blades section for details.
  • Models do not include fan modules or power supplies and must be ordered together with the director model. See Cooling and Power supplies and cables for details.
  • Models do not include power cords and must be ordered together with the director model. See Power supplies and cables for details.

Blades

The X7-4 and X7-8 FC SAN Directors support the port and extension blade options that are listed in the following table.

Blades can be mixed, but the maximum is four for the X7-4 and eight for the X7-8.

Table 3. Port and extension blades
Part number Feature code Description
Port Blades
01KN848 AVGU Lenovo Gen 6 Port Blade FC32-48 (48 transceivers, 32Gbps)
4C57A87792 BVHH Gen 7 Port Blade FC64-64, with 32 x 64Gb (64x64Gb) SWL SFP-DD optics
4M27A09985 B26X Gen 6 Port Blade FC32-64, with 8 x 128Gb (4x32Gb) SWL QSFP optics
4XF7A84049 BR95 Brocade FC32-X7-48 Port Blade w/ 32G SWL Transceivers
4XF7A84050 BR94 Brocade FC32-X7-48 Port Blade w/ 32G LWL Transceivers
4XF7A84046 BR98 Brocade FC64-48 Port Blade w/ 32G SWL transceivers
4XF7A84047 BR97 Brocade FC64-48 Port Blade w/ 64G SWL transceivers
4XF7A84048 BR96 Brocade FC64-48 Port Blade w/ 32G LWL transceivers
4XF7A84079 BRE7 Brocade FC64-48 Port Blade w/ 64G LWL transceivers
SX6 Extension Blades
4M27A14145 B5Z7 Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb SWL SFPs, 1YR
4M27A14146 B5Z8 Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb LWL SFPs, 1YR

Port and extension blades come standard with all ports activated. They also include a specific number and type of transceivers, as indicated in the description of each part number. Additional transceivers and cables can be ordered. See Transceivers and cables for details.

Transceivers and cables

In this section:

Connectivity choices

With the flexibility of the X7-4 and X7-8 Directors, customers can choose the following connectivity technologies:

  • SFP+ ports on the 48-port blades and SX6 extension blade
    • For 64 Gb FC links, customers can use 64 Gb FC SFP+ SWL optical transceivers for distances up to 100 meters on OM4/OM5 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 64 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiber (SMF) optic cables. For extended distances, the 64 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables. (These transceivers are only available on Brocade FC64-48 Port Blade)
    • For 32 Gb FC links, customers can use 32 Gb FC SFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 32 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiber (SMF) optic cables. For extended distances, the 32 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables.
    • For 16 Gb FC links, customers can use 16 Gb FC SFP+ SW optical transceivers for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables. For longer distances, the 16 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ SMF cables. For extended distances, the 16 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables. (These transceivers are NOT supported on Brocade FC64-48 Port Blade)
    • For 10 Gb FC links, customers can use 10 Gb FC SFP+ SW transceivers for distances up to 550 meters on OM4 or up to 300 meters on OM3 50 µ MMF cables, or 10 Gb FC SFP+ LW transceivers for distances up to 10 km on 9 µ SMF cables. 10 Gb FC operations allow metro connectivity by directly utilizing a fiber optic cable between sites or by creating multiple channels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM) technology.
  • SFP-DD ports
    • For 64G FC links, customers can use 64G FC SFP-DD SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables. These transceivers can operate at 64G, 32G, or 16G speeds.
  • QSFP+ ports on the core routing blades:
    • For 128 Gb FC inter-chassis links for connectivity between the X7-4 or X7-8 FC Directors, customers can use 128 Gb (4x 32 Gb) FC QSFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables.
      Note: ICL trunks are formed automatically with corresponding 32 Gbps ports on different QSFP+ transceivers (ICL trunks cannot be formed with the 4x 32 Gbps ports on the same QSFP+ transceiver), and the trunking license is not required.
    • For 64 Gb FC inter-chassis links for connectivity between the X7-4 or X7-8 FC Directors and Brocade DCX 8510 Backbones, customers can use the following transceivers:
      Note: ICL trunks are formed automatically with corresponding 16 Gbps ports on different QSFP+ transceivers (ICL trunks cannot be formed with the 4x 16 Gbps ports on the same QSFP+ transceiver), and the trunking license is not required.
      • 128 Gb (4x 32 Gb) QSFP+ SWL v2 optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables.
      • 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 50 µ MMF cables.
      • 4x 16 Gb FC QSFP+ LWL optical transceivers for distances up to 2 kilometers on parallel 9 µ SMF cables.
    • 1/10 GbE SFP+ and 40 GbE QSFP+ ports on extension blades allow connection to IP WANs and allow Fibre Channel and IP I/O traffic to pass through the IP WAN through extension tunnels.
      • For 1 GbE links, customers can use RJ-45 SFP transceivers with UTP cables up to 100 meters. Customers that need longer distances can use a 1000BASE-SX transceiver, which can drive distances up to 220 meters with 62.5 µ OM1 and up to 550 meters on 50 µ OM2 MMF cables, or the 1000BASE-LX transceivers that support distances up to 10 kilometers on 9 µ SMF cables.
      • For 10 GbE links, customers can use a 10GBASE-SR transceiver that supports distances up to 300 meters on OM3 or up to 400 meters on OM4 50 µ MMF cables. For longer distances, the 10GBASE-LR transceivers can support distances up to 10 kilometers on 9 µ SMF cables.
      • For 40 GbE links, customers can use the 40GBASE-SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 50 µ MMF cables. For longer distances, the 40GBASE-LR4 transceivers can support distances up to 10 kilometers on 9 µ SMF cables. For extended distances, the 40GBASE-ER4 transceivers can support distances up to 40 kilometers on 9 µ SMF cables.
      • 1 GbE RJ-45 management ports on control processor blades: Customers can use UTP cables for distances up to 100 meters.

All port-blades come standard with transceivers that you see reflected in the descriptions. The SX6 extension blades come standard with 16x 32 Gb FC SWL or LWL SFP+ transceivers. The optional ICL bundles include eight Gen 7 FC QSFP+ or eight 4x32G SWL FC QSFP+ transceivers. Additional or different Fibre Channel or Ethernet SFP+, SFP-DD and QSFP+/QSFP28 transceivers can be ordered, if required.

Transceivers

The following table lists the supported transceiver options and optical cables.

Brocade secure transceivers: These new transceivers have features to ensure that you are using genuine Brocade components to maximize performance and reliability and to help avoid issues related to counterfeit products.

Table 4. Supported transceivers
Part number Feature
code
Description Blade support (Y=supported)
FC32-X7-48
FC64-64
FC64-48
FC32-48
SX6
CR32-4
CR32-8
64 Gb FC SFP-DD transceivers
4M27A65427 BPJ5 Brocade Secure 64-Gb SWL SFP-DD Transceiver N Y N N N N N
4M27A65428 BPJ6 Brocade Secure 64-Gb SWL SFP-DD Transceiver 8-pack N Y N N N N N
64 Gb FC SFP+ transceivers
4M27A65425 BF6J Brocade Secure 64GB SWL SFP+ N Y Y N N N N
4M27A65426 BF6K Brocade Secure 64Gb SWL SFP+ (8-pack) N Y Y N N N N
4M27A65433 BQQG Brocade Secure 64Gb LWL SFP+ Transceiver N Y Y N N N N
4M27A65434 BQQH Brocade Secure 64Gb LWL SFP+ Transceiver 8-pack N Y Y N N N N
4M27A65432 BQQF Brocade Secure 64Gb ELWL SFP+ Transceiver (25 km) N N Y N N N N
32 Gb FC SFP+ transceivers
4M27A65416 BF69 Brocade Secure 32Gb SWL SFP+ Y N Y Y Y N N
4M27A65417 BF6A Brocade Secure 32Gb SWL SFP+ (8-pack) Y N Y Y Y N N
4M27A65418 BF6B Brocade Secure 32Gb LWL SFP+ Y Y Y Y Y N N
4M27A65419 BF6C Brocade Secure 32Gb LWL SFP+ (8-pack) Y Y Y Y Y N N
4M27A65424 BF6D Brocade Secure 32Gb ELWL SFP+ (25 km)** Y N Y Y N N N
4M27A65431 BQQE Brocade Secure 32Gb ELWL SFP+ Transceiver V2 (25 km)*/** Y Y Y N N N N
16 Gb FC SFP+ transceivers
4M27A65411 BF64 Brocade Secure 16Gb SWL SFP+ Y N N Y Y N N
4M27A65412 BF65 Brocade Secure 16Gb SWL SFP+ 8-pack Y N N Y Y N N
4M27A65413 BF66 Brocade Secure 16Gb LWL SFP+ (10 km) Y N N Y Y N N
4M27A65414 BF67 Brocade Secure 16Gb LWL SFP+ (10 km) 8pk Y N N Y Y N N
4M27A65415 BF68 Brocade Secure 16Gb ELWL SFP+ (25 km) Y N N Y Y N N
10 Gb FC SFP+ transceivers
4M27A65420 BF6E Brocade Secure 10Gb FC LWL SFP+ Y N Y Y Y N N
4M27A65421 BF6F Brocade Secure 10Gb FC SWL SFP+ Y N Y Y Y N N
QSFP+ FC transceivers
4M27A65422 BF6G Brocade Secure 128Gb (4x 32Gb) SWL QSFP+ N N N N N Y Y
4M27A08820 B145 Brocade 128Gb (4x32Gbps) SWL QSFP+ v2 N   N N N Y Y
4M27A09986 B26T Brocade 128Gb (4x32Gbps) 2KM QSFP+ N   N N N Y Y
01KN805 AVGH Brocade 4x16Gb FC-Compliant SWL QSFP+ N N N N N N N
4XF7A84078 BRA5 Brocade Gen 7 FC SWL QSFP+ N N N N N Y Y
4XF7A84077 BRA6 Brocade Gen 7 FC 2KM QSFP+ N N N N N Y Y
QSFP+/QSFP28 FCoE transceivers
4M27A09989 B26W Brocade 100Gb (4x25GbE) QSFP28 SR4 FCoE N N N N N N N
4M27A09987 B26U Brocade 40Gb (4x10GbE) QSFP+ SR4 FCoE N N N N N N N
4M27A09988 B26V Brocade 40Gb QSFP+ SR4 FCoE, BiDi N N N N N N N
40 Gb Ethernet QSFP+ transceivers
01KN813 AVGL Brocade 40Gb QSFP+ SR4 Optical N N N N Y N N
01KN817 AVGM Brocade 40Gb QSFP+ LR4 Optical N N N N Y N N
01KN821 AVGN Brocade 40Gb QSFP+ ER4 Optical N N N N Y N N
10 Gb Ethernet SFP+ transceivers
49Y4216 0069 Brocade 10Gb SFP+ SR N N N N Y N N
95Y0540 A3AB Brocade 10Gb SFP+ LR N N N N Y N N
01KN837 AVGS Brocade 10GBASE-ZRD DWDM 80km SFP+ N   N N Y N N
1 Gb Ethernet SFP transceivers
01KN825 AVGP Brocade 1000BASE-SX SFP N N N N Y N N
01KN829 AVGQ Brocade 1000BASE-LX SFP N N N N Y N N
01KN833 AVGR Brocade 1000BASE-T SFP N N N N Y N N

* The specific ELWL only operates at 32 Gbps and 16Gbps.
** ELWL Requires same optic type/part number on both ends (no-mixing) to assure interoperability.

Cables

The following table lists the supported optical cables and Cat6 UTP cables.

Table 5. Supported cables
Part number Feature
code
Description Blade support (Y=supported)
FC32-X7-48
FC64-48
FC32-48
SX6
CR32-4
CR32-8
Optical cables for 128 Gb v2 / 4x16 Gb FC SWL, 40 Gb SR4 FCoE, and 40 GbE SR4 QSFP+ transceivers
00VX003 AT2U Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable N N N Y Y Y
00VX005 AT2V Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable N N N Y Y Y
Optical breakout cables for 128 Gb v2 / 4x16 Gb FC SWL, 100 Gb / 40 Gb SR4 FCoE, and 40 GbE SR4 transceivers
00FM412 A5UA Lenovo 1m MPO-4xLC OM3 MMF Breakout Cable N N N Y Y Y
00FM413 A5UB Lenovo 3m MPO-4xLC OM3 MMF Breakout Cable N N N Y Y Y
00FM414 A5UC Lenovo 5m MPO-4xLC OM3 MMF Breakout Cable N N N Y Y Y
OM3 optical cables for 16 Gb FC SWL, 32 Gb FC SWL, 40 Gb SR4 FCoE BiDi, and 1/10 GbE SFP+ transceivers
00MN499 ASR5 Lenovo 0.5m LC-LC OM3 MMF Cable Y Y Y Y N N
00MN502 ASR6 Lenovo 1m LC-LC OM3 MMF Cable Y Y Y Y N N
00MN505 ASR7 Lenovo 3m LC-LC OM3 MMF Cable Y Y Y Y N N
00MN508 ASR8 Lenovo 5m LC-LC OM3 MMF Cable Y Y Y Y N N
00MN511 ASR9 Lenovo 10m LC-LC OM3 MMF Cable Y Y Y Y N N
00MN514 ASRA Lenovo 15m LC-LC OM3 MMF Cable Y Y Y Y N N
00MN517 ASRB Lenovo 25m LC-LC OM3 MMF Cable Y Y Y Y N N
00MN520 ASRC Lenovo 30m LC-LC OM3 MMF Cable Y Y Y Y N N
OM4 optical cables for 16 Gb FC SWL, 32 Gb FC SWL, 40 Gb SR4 FCoE BiDi, and 1/10 GbE SFP+ transceivers
4Z57A10845 B2P9 Lenovo 0.5m LC-LC OM4 MMF Cable Y Y Y Y N N
4Z57A10846 B2PA Lenovo 1m LC-LC OM4 MMF Cable Y Y Y Y N N
4Z57A10847 B2PB Lenovo 3m LC-LC OM4 MMF Cable Y Y Y Y N N
4Z57A10848 B2PC Lenovo 5m LC-LC OM4 MMF Cable Y Y Y Y N N
4Z57A10849 B2PD Lenovo 10m LC-LC OM4 MMF Cable Y Y Y Y N N
4Z57A10850 B2PE Lenovo 15m LC-LC OM4 MMF Cable Y Y Y Y N N
4Z57A10851 B2PF Lenovo 25m LC-LC OM4 MMF Cable Y Y Y Y N N
4Z57A10852 B2PG Lenovo 30m LC-LC OM4 MMF Cable Y Y Y Y N N
UTP Category 6 cables (Green) for 1 GbE RJ-45 SFP transceivers and management ports
00WE123 AVFW 0.75m CAT6 Green Cable N N N Y Y Y
00WE127 AVFX 1.0m CAT6 Green Cable N N N Y Y Y
00WE131 AVFY 1.25m CAT6 Green Cable N N N Y Y Y
00WE135 AVFZ 1.5m CAT6 Green Cable N N N Y Y Y
00WE139 AVG0 3m CAT6 Green Cable N N N Y Y Y
90Y3718 A1MT 10m CAT6 Green Cable N N N Y Y Y
90Y3727 A1MW 25m CAT6 Green Cable N N N Y Y Y
UTP Category 6 cables (Blue) for 1 GbE RJ-45 SFP transceivers and management ports
40K5679 3801 0.6m Blue Cat5e Cable N N N Y Y Y
40K8785 3802 1.5m Blue Cat5e Cable N N N Y Y Y
40K5581 3803 3m Blue Cat5e Cable N N N Y Y Y
40K8927 3804 10m Blue Cat5e Cable N N N Y Y Y
40K8930 3805 25m Blue Cat5e Cable N N N Y Y Y

The SFP-DD Cables specific for the FC64-64 port blade are listed in the following table.

Table 6. SFP-DD Cables specific for the FC64-64 port blade
Part number Feature code Description
OM4 SN to LC (SFP-DD to SFP) optical cables for 64G FC SW SFP-DD transceivers
4X97A81905 BPAF 12U-8020m-MG1M Fiber Cable, SN to LC, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 1M
4X97A81907 BPAG 12U-8020m-MG3M Fiber Cable, SN to LC, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 3M
4X97A81908 BPAH 12U-8020m-MG5M Fiber Cable, SN to LC, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 5M
4X97A81910 BPAJ 12U-8020m-MG10M Fiber Cable, SN to LC, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 10M
4X97A81911 BPAK 12U-8020m-MG15M Fiber Cable, SN to LC, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 15M
4X97A81913 BPAL 12U-8020m-MG25M Fiber Cable, SN to LC, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 25M
4X97A81914 BPAM 12U-8020m-MG30M Fiber Cable, SN to LC, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 30M
OM4 SN to SN (SFP-DD to SFP-DD) optical cables for 64G FC SW SFP-DD transceivers
4X97A81893 BPA8 11U-8020m-MG1M Fiber Cable, SN to SN, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 1M
4X97A81895 BPA9 11U-8020m-MG3M Fiber Cable, SN to SN, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 3M
4X97A81896 BPAA 11U-8020m-MG5M Fiber Cable, SN to SN, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 5M
4X97A81898 BPAB 11U-8020m-MG10M Fiber Cable, SN to SN, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 10M
4X97A81899 BPAC 11U-8020m-MG15M Fiber Cable, SN to SN, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 15M
4X97A81901 BPAD 11U-8020m-MG25M Fiber Cable, SN to SN, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 25M
4X97A81902 BPAE 11U-8020m-MG30M Fiber Cable, SN to SN, OM4 1.6mm Round Duplex Jacket, Magenta, OFNR, 30M

Cabling requirements

The following table lists the cabling requirements for the directors.

Table 7. Cabling requirements
Transceiver Standard Cable Connector
128 Gb (4x 32 Gb) Fibre Channel
128 Gb (4x 32 Gb) FC SWL QSFP+ (4M27A08820, 4M27A65422) FC-PI-6

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables).

850 nm 50 µ MPO-MPO MMF cable:

  • 32GFC: Up to 100 m (OM4) or up to 70 m (OM3).
  • 16GFC: Up to 125 m (OM4) or up to 100 m (OM3).
MPO
128 Gb (4x 32 Gb) FC 2km LWL QSFP+ (4M27A09986) FC-PI-6 32GFC: 1310 nm 9 µ LC-LC SMF cable up to 2 km. LC
64 Gb (4x 16 Gb) Fibre Channel
4x 16 Gb FC SWL QSFP+ (01KN805) FC-PI-5

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables).

16GFC: 850 nm 50 µ MPO-MPO MMF cable up to 100 m (OM4) or up to 66 m (OM3).

MPO
64 Gb Fibre Channel
64 Gb FC SWL SFP+ (4M27A65425, 4M27A65426) FC-PI-6

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables).

850 nm 50 µ LC-LC MMF cable:

  • 64GFC: Up to 100 m (OM4) or up to 70 m (OM3)
  • 32GFC: Up to 100 m (OM4) or up to 70 m (OM3)
  • 16GFC: Up to 125 m (OM4) or up to 100 m (OM3)
LC
64 Gb FC LWL SFP+ (4M27A65433, 4M27A65434) FC-PI-6 1310 nm 9 µ SMF cable:
64GFC, 32GFC, 16GFC: Up to 10 km.
LC
64 Gb FC ELWL SFP+ (4M27A65432) FC-PI-5 1310 nm 9 µ SMF cable:
64GFC, 32GFC, 16GFC: Up to 25 km.
LC
32 Gb Fibre Channel
32 Gb FC SWL SFP+ (4M27A65416, 4M27A65417) FC-PI-6

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables), or the following 850 nm 50 µ MMF cables:

  • 32GFC: Up to 100 m (OM4) or up to 70 m (OM3).
  • 16GFC: Up to 125 m (OM4) or up to 100 m (OM3).
  • 8GFC: Up to 125 m (OM4) or up to 100 m (OM3).
LC
32 Gb FC LWL SFP+ (4M27A65418, 4M27A65419) FC-PI-6 1310 nm 9 µ SMF cable:
  • 32GFC, 16GFC, 8GFC: Up to 10 km
LC
32 Gb FC ELWL SFP+ (4M27A65424, 4M27A65431*) FC-PI-6 1310 nm 9 µ SMF cable:
  • 32GFC, 16GFC, 8GFC: Up to 25 km
  • * 32GFC, 16GFC: Up to 25 km
LC
16 Gb Fibre Channel
16 Gb FC SWL SFP+ (4M27A65411  / 4M27A65412) FC-PI-5 Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables). LC
16 Gb FC LWL SFP+ (4M27A65413 / 4M27A65414) FC-PI-5 1310 nm 9 µ SMF cable:
  • 16GFC, 8GFC: Up to 10 km.
LC
16 Gb FC ELWL SFP+ (4M27A65415) FC-PI-5 1310 nm 9 µ SMF cable:
  • 16GFC: Up to 25 km
LC
10 Gb Fibre Channel
10Gb FC SWL SFP+ (4M27A65420) FC-10GFC 850 nm 50 µ MMF cable:
  • 10GFC: Up to 550 m (OM4) or up to 300 m (OM3)
LC
10Gb FC LWL SFP+ (4M27A65421) FC-10GFC 1310 nm 9 µ SMF cable:
  • 10GFC: Up to 10 km
LC
100 Gb (4x 25 Gb) Fibre Channel over Ethernet
100Gb (4x25Gb) SR4 QSFP28 (4M27A09989) 100GBASE-SR4

Up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables).

850 nm 50 µ MPO-4xLC MMF breakout cable up to 70 m (OM3) or up to 100m (OM4).

MPO
40 Gb Fibre Channel over Ethernet
40Gb (4x10Gb) SR4 QSFP+ (4M27A09987) 40GBASE-SR4

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables).

850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4).

MPO
40Gb SR QSFP+ BiDi (4M27A09988) 40GBASE-SR BiDi

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables).

850 nm 50 µ LC-LC MMF cable up to 100 m (OM3) or up to 150 m (OM4).

LC
40 Gb Ethernet
40 GbE SR4 QSFP+ (01KN813) 40GBASE-SR4

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Cables).

850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4).

MPO
40 GbE LR4 QSFP+ (01KN817) 40GBASE-LR4 1310 nm 9 µ SMF cable up to 10 km. LC
40 GbE ER4 QSFP+ (01KN821) 40GBASE-ER4 1310 nm 9 µ SMF cable up to 40 km. LC
10 Gb Ethernet
10 GbE SR SFP+ (49Y4216) 10GBASE-SR

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables).

850 nm 50 µ LC-LC MMF cable up to 400 m (OM4) or up to 300 m (OM3).

LC
10 GbE LR SFP+ (95Y0540) 10GBASE-LR 1310 nm 9 µ SMF cable up to 10 km. LC
10 GbE DWDM SFP+ (01KN837) 10GBASE-ZRD 1550 nm 9 µ SMF cable up to 80 km. LC
1 Gb Ethernet
1 GbE SX SFP (01KN825) 1000BASE-SX

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Cables).

850 nm 50 µ LC-LC MMF cable up to 550 m.

LC
1 GbE LX SFP (01KN829) 1000BASE-LX 1310 nm 9 µ SMF cable up to 10 km. LC
1 GbE RJ-45 SFP (01KN833) 1000BASE-T UTP Category 5, 5E, or 6 up to 100 meters. RJ-45
Management ports
10/100/1000 Mb Ethernet port 1000BASE-T

Up to 25 m with UTP cables supplied by Lenovo (see Table 4).

UTP Category 5, 5E, or 6 up to 100 meters.

RJ-45
Serial port RS-232 DB-9/RJ-45-to-RJ-45 console cable (comes with the director). RJ-45

Firmware

For details on the latest features supported with the X7-4 & X7-8 FC SAN Directors, see the Administration Guide for the latest available Fabric OS version 9.0 and above:
https://www.broadcom.com/products/fibre-channel-networking/software/fabric-operating-system

Management software

Lenovo offers optional Brocade SANnav™ Management Portal and SANnav Global View software license subscriptions that provide comprehensive visibility into the SAN environment, allow administrators to quickly identify, isolate, and correct problems, and accelerate administrative tasks by simplifying and automating workflows.

SANnav Management Portal is a next-generation SAN management application with a simple browser-based user interface (UI) and with a focus on streamlining common workflows, such as configuration, zoning, deployment, monitoring, troubleshooting, reporting, and analytics.

Lenovo offers the following SANnav Management Portal subscriptions:

  • SANnav Management Portal Base: Designed for mid-sized SANs to manage up to 600 SAN switch ports only (SAN director ports can only be managed with the Enterprise edition).
  • SANnav Management Portal Enterprise: Designed for enterprise-class SANs to manage up to 15 000 SAN switch and director ports.

SANnav Management Portal supports all Brocade SAN switches and platforms that run the Fabric OS® version 7.4 or above, including Lenovo B300, B6505, B6510, DB610S, DB620S, DB400D, DB720S, DB730S, DB800D, Brocade Directors, and FC5022.

With SANnav Global View, administrators can quickly visualize the health, performance, and inventory of multiple SANnav Management Portal instances using a simple, intelligent dashboard and can easily navigate from a global view down to local environments to investigate points of interest. SANnav Global View is designed to manage up to 20 SANnav Management Portal instances.

For more information, refer to the SANnav Management Portal documentation:
http://www.broadcom.com/products/fibre-channel-networking/software/sannav-management-portal#documentation

The following table lists ordering information for the optional SANnav Management Portal and SANnav Global View management tools. After a client has an active SANnav license, Lenovo offers a “license extension/renewal”. This offering provides our clients the flexible to extend their subscription down to a specific end date. This allows clients the ability to align to your company’s budget or align with warranty of your FC SAN switches/directors. Please engage directly with your Lenovo sales representative for more details.

Table 9. SANnav Management Portal and SANnav Global View subscription licenses
Part number Feature code Description
SANnav Management Portal electronic authorization licenses
7S0C0010WW S1K6 Brocade SANnav Mgmt Portal Base Edition - 1YR License 600 ports
7S0C0013WW S1K8 Brocade SANnav Mgmt Portal Base Edition - 3YR License 600 ports
7S0C001KWW S4MB Brocade SANnav Mgmt Portal Base Edition - 5YR License 600 ports
7S0C0011WW S1K7 Brocade SANnav Mgmt Portal Enterprise Edition - 1YR License 15K ports
7S0C0014WW S1K9 Brocade SANnav Mgmt Portal Enterprise Edition - 3YR License 15K ports
7S0C001LWW S4MC Brocade SANnav Mgmt Portal Enterprise Edition - 5YR License 15K ports
SANnav Global View electronic authorization licenses
7S0C0012WW S1D8 Brocade SANnav Global View - 1YR License
7S0C0015WW S1D9 Brocade SANnav Global View - 3YR License
7S0C001JWW S4MA Brocade SANnav Global View - 5YR License

The SANnav licenses are subscription-based with 1-year, 3-year, or 5-year software entitlement and support.

Fibre Channel standards

The SAN Directors supports the standards listed at the following web page:

https://www.broadcom.com/support/fibre-channel-networking/san-standards/standards-compliance

Ethernet standards

The X7 Directors support the following Ethernet standards:

  • IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX)
  • IEEE 802.1p Class of Service (CoS) prioritization
  • IEEE 802.1Q VLAN Tagging
  • IEEE 802.1Qbb Priority-Based Flow Control (PFC)
  • IEEE 802.1Qaz Enhanced Transmission Selection (ETS)
  • IEEE 802.3 10BASE-T Ethernet (CP management interfaces)
  • IEEE 802.3u 100BASE-TX Fast Ethernet (CP management interfaces)
  • IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
  • IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet
  • IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet
  • IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
  • IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
  • IEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb Ethernet
  • IEEE 802.3ba 40GBASE-LR4 long range fiber optics 40 Gb Ethernet
  • IEEE 802.3bm 40GBASE-ER4 extended range fiber optics 40 Gb Ethernet
  • IEEE 802.3bm 100GBASE-SR4 short range fiber optics 100 Gb Ethernet
  • 10GBASE-ZRD DWDM fiber optics 10 Gb Ethernet

Cooling

Models of the X7 Directors do not  include cooling modules (fan assemblies) - the cooling modules must be ordered as well. Each cooling module has two integrated fans.

Two matching cooling modules are required for the X7-4, and three cooling modules are required for the X7-8. Cooling modules provide N+1 fan redundancy (3+1 for the X7-4; 5+1 for the X7-8), and the device can continue operation while one fan assembly is replaced if the fan assembly is replaced immediately. 

Air flow: It is also important to remember your fan tray airflow must match your power supplies!

The following table lists the supported cooling modules.

Table 10. Cooling modules
Part number Feature code Description
01KN895 AVGY FC SAN Director Fan Tray (Non-port side Intake / port-side exhaust)
4XF7A84076 BR90 FC SAN Director Fan Tray (Non-port-side exhaust / port-side intake)

Power supplies and cables

Models of the X7 Directors do not include power supplies - the power supplies must be ordered separately.

Power supply requirements:

  • X7-8: Four matching PSUs must be installed to provide power efficiency and 2+2 redundancy.
  • X7-4: Two matching PSUs must be installed to provide power efficiency and 1+1 redundancy

The AC power supplies are hot-swap 1450 W (100-120 V AC) / 2870 W (200-240 V AC), and each power supply has an IEC 320-C20 connector. Each power supply has two integrated fans that provide non-port side air intake that matches the airflow of the cooling modules.

The High Voltage (HV) Power Supplies has a HVAC/HVDC power cable receptacle connector. The unique power cords is available from Lenovo and is 6m (19.7 ft.) long and contain three colored 14 AWG unterminated wires.

The following table lists the supported power supplies.

Table 11. Power supplies
Part number Feature code Description
Standard AC Power Supplies
4M27A36850 BBCU FC SAN Director PSU (Non-Port Side Intake / port side exhaust)
4XF7A84054 BR93 FC SAN Director PSU (Non-port-side exhaust / port-side intake)
High Voltage (HV) Power Supplies
4XF7A84055 BR92 FC SAN Director High Voltage PSU (Non-port-side intake / port-side exhaust)
4XF7A84057 BR91 FC SAN Director High Voltage PSU (Non-port-side exhaust / port-side intake)

The X7 Directors do not include power cords by default. Up to four rack power cables or line cords should be ordered for the FC SAN Directors depending on the quantity of power supplies.

The following table lists the available power cords.

Table 12. Power cord options
Part number Feature code Description
Rack power cables
39Y7916 6252 2.5m, 16A/125-250V, C19 to IEC 320-C20 Rack Power Cable
Line cords
40K9777 6276 Argentina 4.3m, 16A/250V, C19 to IRAM 2073 Line Cord
40K9775 6277 Brazil 4.3m, 16A/250V, C19 to NBR 14136 Line Cord
40K9774 6288 China 4.3m, 16A/250V, C19 to GB2099.1 Line Cord
40K9776 6285 India 4.3m, 16A/250V, C19 to IS6538 Line Cord
40K9771 6282 Israel 4.3m, 16A/250V, C19 to SI 32 Line Cord
40K9768 6281 Italy 4.3m, 16A/250V, C19 to CEI 23-16 Line Cord
41Y9232 6290 Japan 4.3m, 15A/100V, C19 to JIS C-8303 Line Cord
41Y9233 6291 Japan 4.3m, 15A/200V, C19 to JIS C-8303 Line Cord
41Y9231 6289 Korea 4.3m, 15A/250V, C19 to KSC 8305 Line Cord
40K9770 6280 South Africa 4.3m, 16A/250V, C19 to SABS 164 Line Cord
81Y2391 6549 Switzerland 4.3m, 16A/250V, C19 to SEV 1011 Line Cord
41Y9229 6286 Taiwan 4.3m, 16A/125V, C19 to CNS 10917-3 Line Cord
41Y9230 6287 Taiwan 4.3m, 16A/250V, C19 to CNS 10917-3 Line Cord
40K9767 6278 United Kingdom 4.3m, 13A/250V, C19 to BS 1363/A Line Cord
4L67A08372 B0RV United States 4.3m, 15A/125V, C19 to NEMA 5-15P Line Cord
00D7197 A1NV United States 4.3m, 15A/250V, C19 to NEMA 6-15P Line Cord
Power Cord for High Voltage Power Supply
4L67A84075 BRA7 Universal Power Cord for High Voltage PSU

Rack installation

The X7 Directors come standard with the adjustable 27" to 31" rack mount kits that can be used for 4-post rack installations. The X7-4 also comes standard with the 27” to 31” Airflow Diversion Kit that allow to divert the airflow from the side air vent to the port side. In addition, the X7-8 supports 22" rack mount kit for specific racks and the X7-4 offers an optional 18”to 24” Airflow Diversion Kit.

If required, the Brocade FC SAN Directors can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kits.

The following table lists rack-mount options.

Table 13. Rack-mount options
Part number Feature code Description Maximum
supported
X7-4 rack-mount options
01KN874 AVKB 4-slot Director mid-mount rack kit 1
01KN880 AVKD 18-24" Airflow Diversion Kit for 4-slot Director 1
X7-8 rack-mount options
01KN883 AVH1 8-slot Director 22" rack mount kit 1
01KN886 AVH2 8-slot Director mid-mount rack kit 1

The optional airflow diversion kit for the X7-4 Director is shown in the following figure.

X7-4 Airflow Diversion Kit
Figure 9. X7-4 Airflow Diversion Kit

The optional mid-mount rack kits for the X7-4 and X7-8 Directors are shown in the following figure.

X7-4 (left) and X7-8 (right) Mid-mount Rack Kits
Figure 10. X7-4 (left) and X7-8 (right) Mid-mount Rack Kits

In addition, in order for the X7-4 and X7-8 FC SAN Directors to meet FIPS 140-2 Level 2 Physical Security requirements the tamper-evident seals must be installed (see the following table for ordering information).

Table 14. Tamper-evident security seals
Part number Feature code Description Maximum supported
01KN785 AVGB Brocade FIPS 140-2 High Security Labels and Seals 1

Physical specifications

The X7 Directors have the following dimensions and weight:

Dimensions:

  • X7-8 Director
    • Height: 61.23 cm (24.11 in., 14U)
    • Width: 43.74 cm (17.23 in.)
    • Depth: 61.04 cm (24.04 in.)
  • X7-4 Director
    • Height: 34.45 cm (13.56 in., 8U)
    • Width: 43.74 cm (17.23 in.)
    • Depth: 61.04 cm (24.04 in.)
  • X7-4 with airflow diversion rack-mount kit
    • Height: 40.00 cm (15.75 in., 9U)
    • Width: 43.74 cm (17.23 in.)
    • Depth: 61.29 cm (24.09 in.)

Weight:

  • X7-8 Director
    • 61 kg (78.5 lb) for chassis
    • 8 kg (321.5 lb) maximum fully populated configuration
  • X7-4 Director
    • 5 kg (54 lb) for chassis
    • 68.95 kg (152.0 lb) maximum fully populated configuration

Operating environment

Temperature and humidity, Electrical requirements, and Heat output Information can be found in the Brocade X7-4 and X7-8 Director Hardware Installation Guide. https://www.broadcom.com/roducts/fibre-channel-networking/directors/x7-directors

Warranty upgrades and post-warranty support

The X7 Directors have a three-year warranty.

Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:

  • Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
  • Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
  • Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
  • Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.

Services

Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.

Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

In this section:

Lenovo Advisory Services

Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

Lenovo Plan & Design Services

Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.

Lenovo Deployment, Migration, and Configuration Services

Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.

  • Deployment Services for Storage and ThinkAgile

    A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.

  • Hardware Installation Services

    A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.

  • DM/DG File Migration Services

    Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.

  • DM/DG/DE Health Check Services

    Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.

  • Factory Integrated Services

    A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.

Lenovo Support Services

In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

  • Premier Support for Data Centers

    Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.

  • Premier Enhanced Storage Support (PESS)

    Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.

  • Committed Service Repair (CSR)

    Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.

  • Multivendor Support Services (MVS)

    Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.

  • Keep Your Drive (KYD)

    Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.

  • Technical Account Manager (TAM)

    Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.

  • Enterprise Software Support (ESS)

    Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers.

Lenovo Managed Services

Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.

Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

Lenovo Sustainability Services

  • Asset Recovery Services

    Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.

  • CO2 Offset Services

    Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.

  • Lenovo Certified Refurbished

    Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.

Lenovo TruScale

Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.

Lenovo TruScale is  the unified solution that gives you simplified access to:

  • The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
  • A single-contract framework for full visibility and accountability
  • The global scale to rapidly and securely build teams from anywhere
  • Flexible fixed and metered pay-as-you-go models with minimal upfront cost
  • The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.

For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Regulatory compliance

The X7 Directors conform to the following regulations which can be found in the Hardware Installation Guide, available from the following web page:
https://www.broadcom.com/products/fibre-channel-networking/directors/x7-directors

 

Interoperability

For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic

Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.

External storage systems

Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:

External backup units

The following table lists the external backup options that are offered by Lenovo that can be used in Lenovo FC SAN solutions.

Note: Information provided in this section is for ordering reference purposes only. End-to-end LTO Ultrium configuration support for a particular tape backup unit must be verified through the System Storage Interoperation Center (SSIC):
http://www.ibm.com/systems/support/storage/ssic

Table 15. External Fibre Channel backup options
Part number Description
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
Fibre Channel backup drives for TS4300 Tape Library - Full Height
01KP935 LTO 6 FH Fibre Channel Drive
01KP938 LTO 7 FH Fibre Channel Drive
01KP954 LTO 8 FH Fibre Channel Drive
02JH837 LTO 9 FH Fibre Channel Drive
Fibre Channel backup drives for TS4300 Tape Library - Half Height
01KP933 LTO 6 HH Fibre Channel Drive
01KP936 LTO 7 HH Fibre Channel Drive
01KP952 LTO 8 HH Fibre Channel Drive
02JH835 LTO 9 HH Fibre Channel Drive

For more information, see the list of Product Guides in the Tape Autoloaders and Libraries category:
https://lenovopress.com/storage/tape/library

Rack cabinets

The following table lists the supported rack cabinets.

Table 16. Rack cabinets
ModelDescription
7D6DA007WWThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WWThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA009WWThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWWThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
93604PX42U 1200mm Deep Dynamic Rack
93604EX42U 1200mm Deep Dynamic Expansion Rack
93614PX42U 1200mm Deep Static Rack
93614EX42U 1200mm Deep Static Expansion Rack
93634PX42U 1100mm Dynamic Rack
93634EX42U 1100mm Dynamic Expansion Rack
93074RX42U Standard Rack (1000mm)
93084PX42U Enterprise Rack
93084EX42U Enterprise Expansion Rack

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 17. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
4PU7A93176 C0QH 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93169 C0DA 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93177 C0QJ 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93170 C0D9 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
4PU7A93181 C0QN 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) N Y N N N N N Y N Y N Y N
4PU7A93174 C0D5 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) N Y N Y N N Y Y N N N Y N
4PU7A93178 C0QK 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93171 C0D8 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93182 C0QP 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93175 C0CS 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93180 C0QM 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93173 C0D6 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93179 C0QL 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) N Y N N N N N Y N Y N Y N
4PU7A93172 C0D7 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) N Y N Y N N Y Y N N N Y N
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A90808 C0D4 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A90809 C0DE 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE N N N N N Y Y N N N N N N
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
4PU7A90810 C0DD 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A90811 C0DC 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 N N N N N Y Y N N N N N N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A90812 C0DB 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 N N N N N N N N N Y N N N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 18. Uninterruptible power supply units
Part number Description
Rack-mounted or tower UPS units - 100-125VAC
7DD5A001WW RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
7DD5A003WW RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
Rack-mounted or tower UPS units - 200-240VAC
7DD5A002WW RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A005WW RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A007WW RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
7DD5A008WW RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
7DD5A00AWW RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
Rack-mounted or tower UPS units - 380-415VAC
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Seller training courses

The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.

  1. Family Portfolio: Storage Networking
    2024-10-14 | 15 minutes | Employees and Partners
    Details
    Family Portfolio: Storage Networking

    This course will provide you an overview of the Storage Networking family. After completing this course, you should be able to identify the products in the Storage Networking portfolio and their features, describe product family benefits, and recognize when a specific product should be used.

    Published: 2024-10-14
    Length: 15 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1113r8
  2. Lenovo Data Center Product Portfolio
    2024-05-29 | 20 minutes | Employees and Partners
    Details
    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2024-05-29
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1110r7
  3. Selling and Configuring Gen 7 Fibre Channel Directors
    2023-11-03 | 25 minutes | Employees and Partners
    Details
    Selling and Configuring Gen 7 Fibre Channel Directors

    In this course we will be discussing what Lenovo’s Gen 7 portfolio of offerings and specifically dive into a deeper understanding on how and where to position Gen 7 Directors. We will review how clients are likely to use Directors, plus look at all the different components that go into a director and the decisions required to help build a valid configuration.
    Another objective will be to make sure you can communicate high level some of the benefits of directors and also the advantage of Gen 7 Directors.
    Course objectives:
    1. Understand Lenovo’s full Gen 7 Fibre Channel product portfolio
    2. Understand how and where to position Gen 7 Directors
    3. Communicate the benefits to your clients
    4. Help clients build Director configurations based on their requirements

    Published: 2023-11-03
    Length: 25 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDBS212r2

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®

The following terms are trademarks of other companies:

UltraScale+™ and UltraScale™ are trademarks of Advanced Micro Devices, Inc.

Microsoft® and Excel® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.